Service Schedule
Vacuum Exhaust Heat Exchanger
Solution Pump
Pulley Set Screws & Hub Cap
Screws, Solution Pump Clutch
Chemical Pump & Check Valves
Vacuum Lubrication Lines
Check Valve (Solution Outlet)
Vacuum Pump
Waste Tank Shut-off Float Switch
Inline Gas Filter
Waste Tank Filters/Strainers
* Or as often as required
** Change solution pump crankcase oil after the first 50 hours
***Change engine crankcase oil and filter after the first 25 hours
****Perform drive belt, pulley and hub maintenance after the first 25 hours of operation, and then again at 100 hours
*****AEON PD-XD - Drain and replace oil every 1000 hours, or once a year, whichever comes first.
500 hrs
500 hrs
500 hrs
Shaft Bolt
Drive Pulley
500 hrs
Drive Pulley
500 hrs
Drive Belts
500 hrs
Drive Belts
500 hrs
500 hrs
500 hrs
Engine
500 hrs
Engine
1000 hrs
1000 hrs
1500 hrs
Monthly
Yearly
Engine
Yearly
Engine
Yearly*
Yearly
Engine
2 years
Engine
3 years
86411120 Manual Operators - Peak GTX2 Prochem
Inspect cores and remove debris.
Change oil**
Check for proper torque values. Re-torque, if required****
Inspect, clean and check for pulley groove wear****
Check pulley alignment****
Inspect and clean****
Check belt tension****
Replace diaphragm, plastic disk and check valves.
Check for line obstructions. Replace tubing if cracked or
damaged
Replace in-line fuel filter on engine.
Replace spark plugs.
Inspect, clean, and repair, if needed.
Drain, flush, and replace oil *****
Check for debris hindering movement
Replace Inline Gas Filter
Flush radiator and change engine coolant.
Replace air cleaner element.
Check for damage and blockage. Replace if needed.
Replace radiator hoses and hose clamps.
Replace ignition wires.