Initial Operational Settings

NOTE: Due to temperature and altitude changes, the
optimal settings for each truckmount must be
adjusted after installation. Failure to make these
adjustments may lead to poor unit performance and
premature component failure.
Vacuum Pump
The maximum vacuum pressure obtainable at full
throttle should be 13"Hg. If the unit is drawing a
stronger vacuum (at full sealed suction) than 13" Hg,
adjust the vacuum relief spring to 13" Hg.
22
86411120 Manual Operators - Peak GTX2 Prochem
Engine
Set RPM Values as shown below. Refer to Engine
Operation Manual for adjustment instructions.
Throttle
Idle
13" Hg. Vacuum
Full
500 psi pressure
Full
*±50 rpm tolerance
Load
RPM*
None
1200 rpm
2750 rpm
None
2850 rpm