Troubleshooting - Hyundai HG3300I-A Original Instructions Manual

Inverter generator
Table of Contents

Advertisement

9. TROUBLESHOOTING

Cannot start the engine
Is there any fuel in the tank?
Is the start switch & fuel switch on?
Does the engine has enough oil?
Does the carburetor has enough
gasoline?
Does the spark plug
work?
 If the generator cannot be started for the first time when the oil is added, or the oil is changed,
the oil alarm indicator flashes when pulling the start handle, at this time, the generator should
be shaken back and forth to ensure that the float of the oil alarm floats. If the generator still
does not start, please follow the troubleshooting instruction above.
 Make sure no fuel spills around the spark plug. Spilled fuel may catch fire.
Check spark plug:
 Remove the ignition coil and clean the dirt around the spark plug.
 Remove the spark plug and insert the spark plug into the ignition coil.
 Connect the spark plug side electrode with wire to the metal part of the engine to ground. (You
can use the DC output wire to replace the wire. Use one end of the clip to clamp the metal part of
the engine, and the other end connect to the side electrode of the spark plug.)
 Pull the start handle, spark should jump from the gap.
 Ensure that the engine is cooled down when you check the spark plug, or the high
temperature of the engine and spark plug will cause burns.
Yes
Yes
Yes
Yes
No
Replace
No
Refuel
No
Turn the switch to "ON" position
No
Add recommended oil
No
Check if the tubes are damaged
Still not
working
NOTICE
NOTICE
NOTICE
21
Return the generator to
an authorized dealer for
further assistance

Advertisement

Table of Contents
loading