Settings DIP Switch

8kW

Control board
Switches
Factory setting
SW3-1*
OFF
SW3-2*
OFF
SW3-3
OFF
SW3-4
ON
SW4-1
ON
SW4-2
ON
SW4-3
OFF
SW4-4
OFF
SW5-1
OFF
SW5-2
OFF
SW5-3
OFF
SW5-4
OFF
SW7-1
OFF
SW7-2
OFF
SW7-3
OFF
SW8-1
OFF
SW8-2
OFF
SW8-3*
OFF
SW9*
OFF
*DIP-Switch Function
Switch
Function
SW3-1
Defrosting
SW3-2
Snow guard
monitor
SW8-3
Short com-
pressor start
delay
SW9
Pump down
42
Chapter 5 |
Component description
Notes
*See the table below
*See the table below
*See the table below
Pushbutton
Setting
OFF
ON
Normal
Cold region
Normal
Snow guard
30
5 minutes
minutes
NOTE DIP-Switch markings-Only on original board
The voltage to the outdoor unit must always
be switched off before the DIP switches' set-
tings are changed. When replacing the control
board, set the DIP switches in the same posi-
tion as the previous setting or according to
factory settings.
ON
1
2
3
4
OFF: Marked blue
ON: Marked red