1)
Attach the inner faceplate panel to the insert body using 4 screws
in the locations shown below.
2)
Connect the male end black and red fan switch wires (in the
black casing) to the wire connectors from the fan speed control.
Diagram 3
3) Connect the female ends of the ON/OFF switch - to the ON/OFF
switch in the control box.
Di
E33 FPI Direct Vent Gas Insert

LOW PROFILE FACEPLATE INSTALLATION

Diagram 1
Diagram 2
4
4) Tuck the wires into the clip to keep them away from the insert using
the clip provided. Attach the clip to the rear of the faceplate to en-
sure that the wires do not touch the side of the unit. The power cord
should be run behind the inner faceplate panel.
5) Install the on /off switch - fan speed control box to the left hand
bottom leg of the inner faceplate. Controls located on the left side.
6)
Secure the wires to the back of the inner faceplate with a wire clip
7)
Attach the 2 bottom louver hinges to the bottom fl ange on the
fi rebox using 2 screws per hinge.
Diagram 6