Page 1
Owners & Freestanding Wood Fire Installation Manual www.regency-fire.com.au MODEL: Kingston F3502B Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. 10.31.14 Fireplace Products Australia Pty Ltd. 1 Conquest Way, Hallam, VIC 3803...
Page 2
Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning.
This is a copy of the data badge that accompanies each F3502B Freestanding Wood Fire. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being improved. Check the data badge on the unit and if there is a difference, the label on the unit is the correct one. SAFETY LABEL FOR KINGSTON F3502B MAKE: REGENCY...
installation RESIDENTIAL Too tall a flue may prompt excessive draft 9) In areas with frequent seismic activity, Regency which can result in very short burn times recommends that your unit is secured to the INSTALLATION and excessive heat output. The use of an floor by using the bolt down holes inside the inexpensive flue pipe damper may be helpful pedestal.
installation Logo Installation Rear Heat Deflector STOVE ASSEMBLY Assembly for F3502B 1) Push the PRIOR TO Regency logo The rear heat deflector is supplied with the stove INSTALLATION into the two and must be installed unless the optional airmate holes in the has been selected.
installation MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Please read the section below carefully as clearances depend on whether the Airmate or the Rear Heat Deflector is installed on the stove. Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall. Clearances may only be reduced by means approved by the regulatory authority.
installation THRU-WALL INSTALLATION Minimum vertical of 900mm before any 90˚. If using 45˚, refer to diagram. Horizontal Maximum of 900mm with 6.35mm rise per 0.3m. NOTE: Recommend using 2 - 45º instead of 90º to improve draft and performance (as per diagram). 6"...
Page 10
installation FLOOR PROTECTION A combustible floor must be protected by a non-combustible material (ie. tile, concrete board, or as defined by local codes) extending beneath the heater as follows: From sides : 200mm From Front : 300mm (from Glass) From Back of Appliance: 12 mm 12mm from outer rear heat shield to edge of cement sheet.
installation STEP-BY-STEP 8. To complete your flue installation, install the flue pipe from the stove’s flue collar to the flue FLUE AND support device. CONNECTOR 9. If you are using a horizontal connector, the INSTALLATION flue connector should be as high as possible while still maintaining the 457mm minimum distance from the horizontal connector to the Note: These are a generic set of flue instal-...
installation STAINLESS STEEL SMOKE DEFLECTOR INSTALLATION / REPLACEMENT: The stainless smoke deflector is located in the upper front area of the firebox. The deflector is held in place with 2 bolts Prior to the first fire, ensure deflector is seated properly and secured with 2 hand tightened bolts. Smoke deflector installed with 2 bolts.
installation BRICK INSTALLATION Firebrick is included to extend the life of your stove and radiate heat more evenly. Install all firebricks per the diagram below and place in their correct positions. Do not use a grate. 1. Remove box of firebricks from inside unit. 2.
installation FAN INSTALLATION Fan assembly for use only with the room heater marked to indicate such use. FAN INSTALLATION FAN OPERATION (240V FAN) AUTOMATIC 1) Remove the two screws from the top of the fan housing. To operate the fan automatically, push the bottom switch on the side of the fan housing to "AUTO"...
operating instructions OPERATING IMPORTANT very high temperature the first few times may damage the paint. Burn fires at a moderate level INSTRUCTIONS FIRST FIRE the first few days. With your unit now correctly installed you are now When your installation is completed and inspected 7.
operating instructions SAFETY GUIDELINES 16. The controls of your unit or the air supply pas- Ash Drawer Operating Guideline sages should not be altered to increase firing AND WARNINGS for any reason. 1. Only clean ashes out of the stove when the unit has cooled down.
maintenance DO NOT BURN (WILL VOID WARRANTY): DO NOT BURN GARBAGE OR FLAM- • Treated wood 14. Do not store any fuel closer than 0.6m from your MABLE LIQUIDS SUCH AS GASO- • Tea Tree unit. Do not place wood, paper, furniture, drapes LINE, NAPTHA OR ENGINE OIL.
maintenance MAINTENANCE GLASS REPLACEMENT 4) A small hot fire is preferable to a large smoul- dering one that can deposit creosote within the system. It is very important to carefully maintain your fire- Allow the stove to cool before removing or replacing 5) The chimney and chimney connector should be place stove, including burning seasoned wood and glass.
maintenance CATALYTIC COMBUSTOR ACHIEVING AND MAINTAINING CATALYST LIGHT-OFF: Step 1: Light the stove in accordance with instructions within this manual. The temperature in the stove and the gases entering the combustor must Step 2: With smoke routed through the catalyst (by-pass closed) be raised to between 260C to 371C for catalytic activity to be initiated.
Page 20
maintenance COMBUSTOR ASSEMBLY NOTE: If also replacing the gasket in the bypass door (see next page), remove the lid of the bypass door while it is accessible and complete steps REMOVAL / REPLACEMENT: in Bypass Door Gasket Replacement. The catalytic thermometer on top of the stove should read in the active zone after the stove has been in operation for several hours.
maintenance BYPASS DOOR GASKET REPLACEMENT 4. Slide bypass door assembly forward, lower complete assembly with care. 1. Allow the stove to burn out and cool down, until cool to touch. Lift lid on bypass door assembly to reveal gasket. 2. Open stove door to access bypass door. 4.
maintenance SECONDARY AIR TUBE REMOVAL / DOOR CATCH INSTALLATION ADJUSTMENT 1. Allow the stove to burn out and cool down, until cool to touch. The door catch may require adjustment as the door gasket compresses after a few fires. The door catch compression may require adjustment to renew 2.
Page 23
maintenance Annual Maintenance Completely clean out entire unit Annually Inspect air tube, Catalytic Combustor and bricks Replace any damaged parts. Adjust door catch assembly If unable to obtain a tight seal on the door - replace door gasket seal. Readjust door catch after new gasket installed. Inspect condition and seal of: Glass Gasket Door Gasket...
parts list F3502B STOVE BRICK LAYOUT 042-960 Brick Set Complete Fire bricks Quantity Size 114mm x 229mm 51mm x 229mm 89mm x 114mm 44mm x 114mm 114mm x 2194mm F3502B Freestanding Woodfire |...
parts list DOOR ASSEMBLY Part # Description Part # Description 042-201 Door cast black (F3502B) 846-530 5/8" Medium Door gasket kit 106-541/P Aligner assembly 042-021 Gasket bracket 156-514 Removable cast handle assembly 904-513 Hex bolt 1/4-20 x 3/4 LG. 940-416/P Door glass 904-525 Washer 1/4"...
Page 30
fi reboxes (see below).** NOTE: The Catalytic Combustor is covered by Regency Fireplace Products for the fi rst six (6) years. See warranty details on next page. **FPI is not liable for freight or labour on any wood burning appliance replaced in fi eld.
Page 31
Warranty (fi rst six (6) years). Regency Fireplace Products will replace, at no charge to the consumer - 'one' only, VERSAGRID CATALYTIC CONVERTER that ceases to func- tion within three (3) years from the date of purchase by the original consumer, provided that the following conditions are met: (1) A copy of the original invoice that include place and date of purchase must be submitted with the warranty claim.
Page 32
Register your Regency warranty online ® www.regency-fire.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.