Lincoln Electric Aspect 230 DC Operator's Manual page 8

Table of Contents

Advertisement

ASPECT
®
230 DC
TECHNICAL SPECIFICATIONS ASPECT
(K4346-1)
POWER SOURCE INPUT VOLTAGE
AND CURRENT
Max Input Amperes
120V/208V/230V/400V/460V
Input Voltage ± 10%
Idle Power
Power Factor
@ Rated Output
RATED OUTPUT
Input Power
PHASE
120V
Single
Phase
Single or
Three
Phase
OUTPUT RANGE
Phase
Type of
Output
120V
GTAW DC
SMAW DC
Single Phase
208-460 VAC
GTAW DC
Single or
SMAW DC
Three Phase
Thermal tests have been performed at ambient tem-
perature. The duty cycle (duty factor) at 40°C has
been determined by simulation.
230 DC
®
3-Phase NA/19/17/10/9
1-Phase 31/33/31/18/16
120
4
V Single Phase
208-460V Single or 3 Phase
(includes 220, 380, 400)
100 Watts Max.
.95
Duty
Rated Output
Cycle
Current and Voltage
100%
GTAW 110 A / 14.4 V
SMAW 70 A / 22.8 V
60%
GTAW 125 A / 15 V
SMAW 85 A / 23.4 V
35%
GTAW 150 A / 16 V
SMAW 100 A / 24 V
100%
GTAW 160 A / 16.4 V
SMAW 120 A / 24.8 V
60%
GTAW 190 A / 17.6 V
SMAW 140 A / 25.6 V
35%
GTAW 230 A / 19.2 V
SMAW 180 A / 27.2 V
Output Current
Maximum Open
Range
Circuit Voltage
2-150 Amps
105 Volts Max.
5-100 Amps
91 Volts Max.
2-230
105 Volts Max.
5-180
91 Volts Max.
RECOMMENDED FUSE SIZES 1
INPUT
VOLTAGE /
PHASE /
FREQUENCY
120
4
/1/50/60
208/1/50/60
230/1/50/60
400/1/50/60
460/1/50/60
208/3/50/60
230/3/50/60
380-415/3/50/60
460/3/50/60
PHYSICAL DIMENSIONS
HEIGHT
WIDTH
16.5 in.
9.7 in.
419 mm
246 mm
OPERATING TEMPERATURE RANGE
-10°C to +40°C (-4°F to +104°F)
STORAGE TEMPERATURE RANGE
-20°C to +85°C (-40°F to +185°F)
IP23
1. Based on U.S. National electrical Code
2. Also called " inverse time" or "thermal / magnetic" circuit break-
ers; circuit breakers that have a delay in tripping action that
decreases as the magnitude of the current increases
3. In some countries, U
is also known as open circuit voltage OCV
0
(see CAN/CSA-W117.2)
4. The rated output is available when connected to a 30A branch
circuit. When connected to a 15A branch cicuit the ratings are
3
75A for STICK at a 10% duty cycle and 105A for TIG at a 10%
duty cycle. When connected to a 20A branch circuit the ratings
are 90A for STICK at a 10% duty cycle and 120A for TIG at a
10% duty cycle.
A-1
INSTALLATION
MAXIMUM
TIME DELAY FUSE
INPUT AMPERE
OR
RATING
BREAKER
AMPERAGE
31 A
30
33 A
50
31 A
50
18 A
30
16 A
30
19 A
30
17 A
20
10 A
20
9 A
20
DEPTH
WEIGHT
19.9 in.
46.5 lbs. (21kg.)
506 mm
2