Lincoln Electric Aspect 230 DC Operator's Manual page 19

Table of Contents

Advertisement

ASPECT
®
230 DC
Memory Recall Settings
(See Figure B.17)
In order to recall process settings it is first necessary to press the
memory button twice so that the "memory recall" is illuminated.
Once the desired memory location has been selected using the
control knob, pressing and holding the memory button for 3 seconds
will recall the settings from that location. During the 3 second hold
period the "memory recall" icon will flash. After 3 seconds the
recalled settings will be displayed.
FIGURE B.17
V
MEM
S
PROCESS
A
S
SEL
OUTPUT
Summary:
(See Figure B.18)
1. Press Memory button to highlight "Memory Recall" icon
2. Turn Control Knob to select memory location
3. Press and hold memory button for 3 seconds
FIGURE B.18
V
MEM
A
S
%
PROCESS
A
S
SEL
OUTPUT
A
RECL
5
A
A
S
%
%
A
Hz
S
3 Seco
A
RECL
5
A
S
%
A
Hz
S
Status Lights:
(See Figure B.19)
There are 4 status lights located between the voltage and amperage
displays. These LEDs illuminate to display the following:
1. Power on – This light indicates that power has been applied to
the machine and it is ready to weld. A blinking light indicates that
the start up sequence is in process. When the light turns fully ON,
the machine is ready to weld.
2. Thermal Fault – The thermal light will turn on if the machine has
overheated. Welding may continue after the machine has cooled
and the light switches off.
3. Remote – When a remote output control is connected to the 6 pin
connector on the front of the machine, this LED will turn on.
4. VRD – When operating in VRD Mode (Voltage Reduction Device)
this LED will light up when the output voltage is below 12 Volts.
VRD may be turned ON / OFF in Setup Menu "SYS."
FIGURE B.19
1
3
B-7
OPERATION
2
4

Hide quick links: