Daikin ERLA-DV17 Installer's Reference Manual page 42

Table of Contents

Advertisement

6
|
Application guidelines
Heat pump convectors – Multiple rooms
Installer reference guide
42
For more information about connecting the electrical wiring to the unit, see:
-
"9.2 Connections to the outdoor
-
"9.3 Connections to the indoor
For each room, a shut-off valve (field supplied) is installed to avoid leaving water
supply when there is no heating or cooling demand.
A bypass valve must be installed to make water recirculation possible when all
shut-off valves are closed. To guarantee reliable operation, provide a minimum
water flow as described in table "To check the water volume and flow rate" in
"8.5 Preparing water
The user interface integrated in the indoor unit decides the space operation
mode. Mind that the operation mode on each room thermostat must be set to
match the indoor unit.
The room thermostats are connected to the shut-off valves. They are also
connected to the indoor unit (X2M/35 and X2M/30) -via a relay (field supplied)-
to give feedback when operation is needed. The indoor unit will supply leaving
water as soon as there is a request from one of the rooms.
Configuration
Setting
Unit temperature control:
#: [2.9]
Code: [C-07]
Number of water temperature zones:
#: [4.4]
Code: [7-02]
External room thermostat for the main
zone:
#: [2.A]
Code: [C-05]
Benefits
Compared with radiators for one room:
Comfort. You can set the desired room temperature, including schedules, for
each room via the room thermostats.
Setup
4
unit" [
 123]
4
unit" [
 126]
4
piping" [
 104].
1 (External room thermostat):
Unit operation is decided by the
external thermostat.
0 (Single zone): Main
1 (1 contact): When the used
external room thermostat or heat pump
convector can only send a thermo ON/
OFF condition. No separation between
heating or cooling demand.
B
A
a
Value
C
a
ERLA11~16D + EBVH16SU23D
Daikin Altherma 3 R F
4P655196-1A – 2022.05