Daikin ERLA-DV17 Installer's Reference Manual page 226

Table of Contents

Advertisement

11
|
Configuration
Installer reference guide
226
#
Code
[9.8.8]
N/A
Allowed heaters during preferential kWh rate power supply
Do NOT use 1 or 3. Setting [D-00] to 1 or 3 when [D-01] is set to 1 or 2 will reset
[D-00] back to 0, as the system does not have a booster heater. Only set [D-00] to
the values in the table below:
[D‑00]
0
2
Smart Grid operation modes
The 2 incoming Smart Grid contacts (see
can activate the following Smart Grid modes:
Smart Grid contact
1
0
0
1
1
Free running:
The Smart Grid function is NOT active.
Forced off:
The unit forces OFF the compressor and the backup heater.
The protective functions (room frost protection, tank disinfection) and defrost
are NOT overruled (capacity will not be limited for these functions)
Also see
"Protective
functions" [
Recommended on:
Limit setting kW
Restriction: Only applicable if:
[9.8.4]=Smart grid.
There is no pulse meter (power meter) for
photovoltaic
Electricity meter 2 = None)
Normally, when a pulse meter is available, the
following happens:
The pulse meter measures the power
produced by the photovoltaic panels.
The unit limits its power consumption during
the Smart Grid's "Recommended ON" mode to
only use the power provided by the
photovoltaic panels.
However, when the pulse meter is not available,
you can still limit the unit's power consumption
using this setting (Limit setting kW). This
prevents overconsumption and thus requiring
the use of power from the grid.
Backup heater
Forced OFF
Allowed
"9.3.11 To connect a Smart
[9.8.5] Smart grid operation
2
0
Free running
1
Forced off
0
Recommended on
1
Forced on
4
 235].
Description
panels
available
Compressor
Forced OFF
Grid" [
mode
ERLA11~16D + EBVH16SU23D
Daikin Altherma 3 R F
4P655196-1A – 2022.05
([9.A.2]
4
 141])

Advertisement

Table of Contents
loading

Table of Contents