Field settings table
Breadcrumb Field code
Setting name
9.I
[3-02]
--
9.I
[3-03]
--
9.I
[3-04]
--
9.I
[3-05]
--
9.I
[3-06]
What is the maximum desired room temperature in heating?
9.I
[3-07]
What is the mimimum desired room temperature in heating?
9.I
[3-08]
What is the maximum desired room temperature in cooling?
9.I
[3-09]
What is the minimum desired room temperature in cooling?
9.I
[3-0A]
What is the pump model?
9.I
[4-00]
What is the BUH operation mode?
9.I
[4-01]
Which electric heater has priority?
9.I
[4-02]
Below which outdoor temperature is heating allowed?
9.I
[4-03]
Operation permission of the booster heater.
9.I
[4-04]
Water pipe freeze prevention
9.I
[4-05]
--
9.I
[4-06]
Emergency
9.I
[4-08]
Which power limitation mode is required on the system?
9.I
[4-09]
Which power limitation type is required?
9.I
[4-0A]
Backup heater configuration
9.I
[4-0B]
Automatic cooling/heating changeover hysteresis.
9.I
[4-0D]
Automatic cooling/heating changeover offset.
9.I
[4-0E]
--
9.I
[5-00]
Equilibrium: Deactivate backup heater (or external backup heat source in case of a
bivalent system) above the equilibrium temperature for space heating?
9.I
[5-01]
What is the equilibrium temperature for the building?
9.I
[5-02]
Space heating priority.
9.I
[5-03]
Space heating priority temperature.
9.I
[5-04]
Set point correction for domestic hot water temperature.
9.I
[5-05]
What is the requested limit for DI1?
9.I
[5-06]
What is the requested limit for DI2?
9.I
[5-07]
What is the requested limit for DI3?
9.I
[5-08]
What is the requested limit for DI4?
9.I
[5-09]
What is the requested limit for DI1?
9.I
[5-0A]
What is the requested limit for DI2?
9.I
[5-0B]
What is the requested limit for DI3?
9.I
[5-0C]
What is the requested limit for DI4?
9.I
[5-0D]
Backup heater voltage
9.I
[5-0E]
BUH DHW thermo ON delay
9.I
[6-00]
The temperature difference determining the heat pump ON temperature.
9.I
[6-01]
The temperature difference determining the heat pump OFF temperature.
9.I
[6-02]
What is the capacity of the booster heater?
9.I
[6-03]
What is the capacity of the backup heater step 1?
9.I
[6-04]
What is the capacity of the backup heater step 2?
9.I
[6-07]
--
9.I
[6-08]
What is the hysteresis to be used in reheat mode?
(*1) *6V_(*2) *9W_(*3) EBB*_(*4) EBV*_
(*5) *X*_(*6) *H*_(*7) *11*_(*8) *16*_
(*9) *SU*_(*10) *18*_(*11) *23*
Range, step
Default value
1
4
2
1
R/W
18~30°C, step: 1°C
30°C
R/W
12~18°C, step: 1°C
12°C
R/W
25~35°C, step: 1°C
35°C
R/W
15~25°C, step: 1°C
15°C
R/O
0: pump model 0 (*7)
1: pump model 1 (*8)
R/W
0: Disabled
1: Enabled
2: Only DHW
R/W
0: None
1: BSH
2: BUH
R/W
14~35°C, step: 1°C
35°C
R/W
0: Restricted
1: Allowed
2: Overlap
3: Compressor off
4: Legionella only
R/O
0: Continuous pump operation
1: Non continuous pump operation
2: OFF
0
R/W
0: Manual
1: Automatic(normal SH/DHW ON)
2: Auto red SH/DHW ON
3: Auto red SH/DHW OFF
4: SH ON/DHW OFF
R/W
0: No limitation
1: Continuous
2: Digital inputs
R/W
0: Current
1: Power
R/W
0: 1
1: 1/1+2
2: 1/2
3: 1/2 + 1/1+2 in emergency
R/W
1~10°C, step: 0,5°C
1°C
R/W
1~10°C, step: 0,5°C
3°C
6
R/W
0: No
1: Yes
R/W
-15~35°C, step: 1°C
0°C
R/W
0: Disabled
1: Enabled
R/W
-15~35°C, step: 1°C
0°C
R/W
0~20°C, step: 1°C
10°C
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W (*1)
0: 230V, 1~ (*1)
R/O (*2)
1: 230V, 3~ (*1)
2: 400V, 3~ (*2)
R/W
0: Disable
1: Enable (variable delay HP dependent)
2: Enable (fixed delay HP dependent)
R/W
2~40°C, step: 1°C
8°C
R/W
0~10°C, step: 1°C
0°C
R/W
0~10kW, step: 0,2kW
3kW (*3)
0kW (*4)
R/W
0~10kW, step: 0,2kW
2kW (*1)
3kW (*2)
R/W
0~10kW, step: 0,2kW
4kW (*1)
6kW (*2)
R/W
0~200W, step: 10W
0W
R/W
2~20°C, step: 1°C
10°C
9/13
Installer setting at variance with
default value
Date
Value
4P655201-1 - 2021.09