enphase IQ8 Series Installation And Operation Manual page 29

Microinverters
Hide thumbs Also See for IQ8 Series:
Table of Contents

Advertisement

Maximum
microinverters per 20 A (max) AC branch circuit
5
230 VAC (single-phase)/400 VAC (multi-phase)
European weighted efficiency
Total harmonic distortion
Ambient air temperature range
Nighttime power loss
Storage temperature range
Compatibility
Dimensions (without mounting brackets)
DC connector type
Weight
IP Rating
Torque specifications for fasteners
(Do not over torque)
Cooling
Relative humidity range
Approved for wet locations
Altitude
Pollution degree
Standard warranty terms
Compliance
Earthing
Monitoring
Communication
5.
Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.
6.
Minimum two IQ8 Series Microinverters shall be required in the system.
29
Miscellaneous parameters
IQ8AC-72-M-INT Microinverter parameters
Features and specifications
IQ8AC-72-M-INT Microinverter parameters
© 2023 Enphase Energy Inc. All rights reserved.
IQ8AC/IQ8HC Installation and Operation Manual
%
%
°C
-40
mW
°C
-40
54-cell/108-half-cell, 60-cell/120-half-cell, 66-
cell/132-half-cell, 72-cell/144-half-cell
212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2")
Stäubli MC4
Outdoor - IP67
6 mm mounting hardware: 5 N m
8 mm mounting hardware: 9 N m
Natural convection - no fans
4% to 100% (condensing)
< 2600 m
http://enphase.com/warranty
With IQ Relay:
AS/NZS 4777-2:2020
6
Safety:
EN IEC 62109-1, EN IEC 62109-2
EMC:
EN IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-
3, EN IEC 50065-1, 50065-2-1
EN55011 (At STC within MPP range)
The DC circuit meets the requirements for ungrounded
PV arrays. Ground fault protection (GFP) is integrated
into the class II double-insulated microinverter.
Enphase Installer Platform and Enphase App
monitoring options. Both options require an IQ
Gateway
Power line communication (PLC)
11 (L+N)/39 (3L+N)
96.6
<5
+65
50
+85
1.1 kg
Yes
PD3
June 2023
USM-00005-2.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iq8acIq8hc