5.3 Selection of Installation Location
The BU module is for indoor use. If installing in the outdoors, the location must be away from wind and
rain. Otherwise, it maybe causes water leakage, electric shocks or fire etc.
The
BU module must be installed on a firm and solid support
module and the mounting surface must be horizontal plane. The BU module can be chosen to install in
the ceiling,
such as the ceiling of parlor, corridor, balcony,
There is enough space for the installation and maintenance.
Avoid direct sunlight or other heat sources exist
Do not install in location that is hot or humid for long periods of time.
Avoid the BU module installed in the bedroom and study, where these places need to be quiet
BU module cannot be installed in the place of inflammable and explosive materials and severe dust,
smoke and the other air pollution, such as the kitchen.
There is enough space to install drainage pipe, so that the condensed water can be discharged.
Caution!
Installation at the following places might lead to the air conditioner malfunction. If it is unavoidable, please
contact the appointed service center.
A place which is full of machine oil;
A region with saline-sodic soil near the sea;
A place where the sulphide fog exists, such as the sulphur spring;
A place where the high frequency facilities exist, such as radio equipment, electric welder and medical
equipment;
An environment with special conditions.
①
Liquid piping of indoor
side
⑤
Gas piping of outdoor unit
②
③
Hanger metal
unit side
⑥
⑦
Drain hole
side
which can withstand the weight of the
storeroom
and etc
Super Free Match
Service Manual
④
Electrical
equipment plate
⑧
Printed circuit
board
INSTALLATION
85