Technical Specification Of User Interfaces; Standards And Regulations; Type Tests And Environmental Conditions; Type Tests And Environmental Conditions - Advantech SmartStart SL306 User Manual

Lte industrial router
Hide thumbs Also See for SmartStart SL306:
Table of Contents

Advertisement

7.2 Technical specification of user interfaces

Connector
Standard
Min. data rate
Max. data rate
Max. total cable length
(300 Bd, 200 nF/km)
Table 12: Technical specification of user interfaces

7.3 Standards and Regulations

The router complies with the following standards and regulations.
Parameter
Safety
Environmental
National

7.4 Type Tests and Environmental Conditions

Phenomena
Dry heat
Cold
Damp heat
Temperature variation
Table 14: Type tests and environmental conditions
ETH
RJ45
IEEE 802.3
10 Mbps
100 Mbps
100 m
Description
IEC 62368-1, EN 62311
China RoHS, RoHS and WEEE compliant
CCC compliant
Table 13: Standards and Regulations
Test
Description
EN 60068-2-2
Operation
Storage
EN 60068-2-1
Operation
Storage
EN 60068-2-30,
+55 C / +25 C, 12 h – 12 h, 2 cycles
test Db
EN 60068-2-14 Nb
-40 C / +75 C, 3 h / 3 h, 2 cycles, 3 K/min
29
SmartStart SL306
RS232
DB9 Female
300 bps
230400 bps
20 m
Test levels
+75 C, 40 % rel. humidity,
16 hours
+85 C, 40 % rel. humidity,
16 hours
-40 C, 16 hours
-40 C, 16 hours

Advertisement

Table of Contents
loading

Table of Contents