Rs232-Rs485-Eth Interface; Version With Rs232-Rs485-Eth Interface; Connections Of The Ethernet Connector - Advantech SmartFlex SR304 User Manual

Lte industrial router
Hide thumbs Also See for SmartFlex SR304:
Table of Contents

Advertisement

5.10.3 RS232-RS485-ETH interface

This interface board includes a panel RJ45 connector for Ethernet connection (ETH2 in
the figure), and four-pin and three-pin terminal block connectors for RS232 and RS485 con-
nection. The insulation strength is up to 2.5 kV between the ETH2 and RS485 interfaces and
from the rest of the router, too. The RS232 interface is not insulated from the rest of the router.
State indication is displayed by LEDs above each connector, as shown in the table below.
These router versions comply with the standards and temperature ranges stated in Chap. 7.1.
Figure 45: Version with RS232-RS485-ETH interface
Connection of ETH connector:
Pin
Signal
1
TXD+
2
TXD-
3
RXD+
4
5
6
RXD-
7
8
Table 25: Connections of the Ethernet Connector
Description
Transmit Data – positive pole
Transmit Data – negative pole
Receive Data – positive pole
Receive Data – negative pole
Figure 46: Ethernet connector
35
SmartFlex SR304
Direction
Input/Output
Input/Output
Input/Output
Input/Output

Advertisement

Table of Contents
loading

Table of Contents