14 Fold the ribbon cable near the connector to align it with the J2 pins on the
display board, ensuring that the notch on the ribbon cable is facing toward
the display board. Carefully work the ribbon cable connector onto the J2
pins until firmly seated. Route the cable flat beside the power supply
board, gathering excess cable under the display. Be careful not to press
the cable beneath the alignment posts or studs of the base. See Figure 50
on
page
Note: Do not allow R5 on the power supply board to become bent during
this procedure.
15 Replace the base. If the telephone is equipped with an MPDA or MCA,
reconnect the data cable to the base telephone jack and replace the
footstand (ensuring that the MPDA or MCA cable does not get pinched
between the base and the footstand). Make sure the footstand is firmly
seated in the base.
Note: Place the label supplied with the display on the outside of the
bottom cover of the telephone. This allows proper identification and
tracking of the option level of the set.
16 Tighten all screws, reconnect all cords, and place the telephone in the
normal operating position.
17 Perform the self-test (see) and acceptance test procedures. See LD 31 in
the Software Input/Output: Administration (553-3001-311).
External Alerter Board
Use Procedure 34 on
M2006, M2008, M2216ACD, or M2616 telephone. See Figure 51 on
page 182
device.
176.
End of Procedure
page 180
for information on hooking up the third-party External Alerter
M2000 add-on modules
to add an External Alerter Board to the