SMC Networks ISE80 Operation Manual page 52

Digital pressure switch
Hide thumbs Also See for ISE80:
Table of Contents

Advertisement

Model No.
Enclosure
Ambient temperature
Environment
Ambient humidity
Withstand voltage
Insulation resistance
Temperature characteristic
Lead wire
Standard
○Piping specifications
Model No.
Port size
Mass (Bottom ported)
Mass (Rear ported)
Leakage
○Analogue output
Voltage output
Range
Vacuum
Compound
Positive pressure
∗: Analogue output is 0.8 [V] or 3.2 [mA] at the pressure A.
ISE80
(positive pressure)
Operation: 0 to 50
Operation, Storage: 35 to 85% RH (No condensation)
250 VAC for 1 minute Between wires and case
2 MΩ or more (50 VDC by megameter) Between wires and case
±3% F.S. (25 °C Ambient temperature range))
Oil resistant vinyl cabtyre cable
3 cores (N.P)
4 cores (A.B)
5 cores (R.T.S.V) Outside diameter of insulator: 0.95 mm
CE marked (EMC directive/RoHS directive), UL/CSA
02
N02
R1/4
NPT1/4
117 g
118 g
89 g
90 g
Pa●m
-5
1x10
Rated pressure range
0.0 to -101.0 kPa
-100.0 to 100.0 kPa
-0.100 to 1.000 MPa
-0.100 to 2.00 MPa
-51-
ISE80H
ZSE80
(positive pressure)
(vacuum)
IP65
o
o
C, Storage: -10 to 60
C (No condensation or freezing)
φ3.5, 2 m
Sectional area of conductor: 0.15 mm
F02
C01
G1/4
Rc1/8
-
114 g
86 g
86 g
3
/s
Current output
A
B
-
0
-
-100 kPa
-0.1 MPa
0
-0.1 MPa
0
ZSE80F
(compound)
2
(AWG26)
A2
B2
URJ1/4
TSJ1/4
120 g
111 g
92 g
83 g
Pa●m
-10
3
1x10
/s
C
-101.0 kPa
100 kPa
1 MPa
2 Mpa
No.PS※※-OMM0003-J

Advertisement

Table of Contents
loading

Table of Contents