Fault No.
Fault
The pressure
display accuracy
12
does not satisfy
the specifications.
The display units
13
cannot be
changed.
The buttons cannot
14
be operated.
The product is
15
loose.
The product is
16
noisy.
The operation is
17
unstable.
(chattering)
Possible cause
Check if any foreign matter has
Foreign matter
entered the pressure port.
Air and fluid
Check if air or fluid are leaking from
leakage
the piping.
Check if the product satisfies the
Insufficient
specified accuracy after 10 minutes
warm-up time
warm up time.
Product failure
Improper model
selection (selection
Check if there is an "-M" at the end
of model "without
of the part number printed on the
units selection
product
function")
Product failure
Key lock mode
Check if the key lock mode is turned on. Turn off the key lock mode.
Product failure
Check that the panel mount adapter
Incorrect
and the product are correctly
installation
assembled.
Product failure
Check if air or fluid are leaking from
Air or fluid leakage
the piping.
Product failure
Pressure source
(1) Check the set pressure
fluctuation, small
hysteresis or the
(hysteresis)
response time is
(2) Check the response time
too short.
(1) Check the power supply wiring.
Incorrect wiring or
(2) Check if there is bending stress
broken lead wire
applied to any parts of the lead
wire.
Product failure
-48-
Investigation method
Countermeasure
Install a 5 µm filter to prevent
foreign matter from entering
the pressure port. Also, clean
the filter regularly to prevent
drainage deposits.
Rework the piping.
If an excessive tightening
torque is applied, the
mounting bracket, screws or
the product may be damaged.
After energizing, the display and
output can drift. For detecting
fine pressures, warm up the
product for 10 to 15 minutes.
Replace the product.
"M" in the part number means
that the units cannot be
changed.
(kPa↔MPa can be selected)
∗: The units selection function is
not available in Japan due to a
new measurement law.
∗: It is fixed to the SI unit "kPa",
"MPa".
Replace the product.
Replace the product.
Mount the product on the
panel correctly.
Replace the product.
Rework the piping.
If an excessive tightening
torque is applied, the
mounting bracket, screws or
the product may be damaged.
Replace the product.
(1) Check the pressure
setting.
(2) Reset the function
settings.
(1) Correct the wiring
(2) Correct the wiring
conditions (reduce the
tensile force and increase
the bending radius).
Replace the product.