Set the bath fill water volume
4.
Press the BATH FILL VOLUME up () button or the
BATH FILL VOLUME down () button.
The first press of either the BATH FILL VOLUME
up () button or the BATH FILL VOLUME
down () button will display the last selected bath fill
water volume setting in the bath fill water volume
display panel and the bath fill indicator light will glow.
While the bath fill water volume is displayed, each
subsequent press of the BATH FILL VOLUME
up
()
button
down () button will change the water volume setting
by 10 litres.
When the BATH FILL VOLUME up () button is
pressed and the water volume setting is increased,
the voice prompt will sound;
"caution, bath fill water volume has been increased,
bath may overflow"
When the BATH FILL VOLUME down () button is pressed and the water volume setting is
decreased, the voice prompt will sound;
"bath fill water volume has been decreased"
Pressing the BATH FILL VOLUME up () button or BATH FILL VOLUME down () button
continuously will scroll the water volume setting.
A maximum volume of 990 litres and a minimum volume of 10 litres can be set. The maximum volume
of 990 litres is achieved in 10 litre increments up to 500 litres, then 990 litres is the next setting.
The selected bath fill water volume will be displayed and the bath fill indicator light will glow on all
Deluxe controllers.
°C
8 8
The bath fill water volume display panel will go blank
and the bath fill indicator light will go out 3 seconds
10L
after the last press of either of the volume adjustment
X
buttons.
The set volume will be remembered when the
) button is next pressed "on".
bath fill (
8 8
5.
Close the front panel on the Deluxe controller.
Turn on the Bath Fill function
6.
Press the bath fill (
On all Deluxe controllers:
The bath fill operating light will glow.
The bath fill temperature setting will appear on
the temperature display panel.
The bath fill water volume will appear on the
bath fill water volume display panel.
The bath fill indicator light will glow.
The voice prompt will sound;
"please set bath water volume and bath
temperature, then open the hot water tap"
or
BATH
FILL
VOLUME
°C
10L
X
) button.
TEMPERATURE CONTROL – DELUXE
1 2 0
BATH (l)
BATH FILL
VOLUME
B1
Bath Fill
1. 2.
3.
Bath
Bath
Water
Fill
Volume
Temp
Set Bath Fill
Press Bath
Water Volume
Fill Button
and Temperature
(Red light on)
Hot Water
1.
PRIORITY
Light on
Press
BATH (l)
Rheem
1 2 0
BATH (l)
Rheem
35
°C
"caution,
bath fill water
BATH FILL
volume has been
TEMPERATURE
increased,
bath may overflow"
or
"bath fill water
4.
5.
6.
7.
volume has been
Open
Bath Fill
Close
hot tap
hot tap
completed
decreased"
(automatic)
Press Bath
Fill Button
Fill Button
(Red light flashes)
(Red light off)
2.
3.
4.
Adjust
Open
Temperature
hot tap
°C
°C
4 0
"please set
bath water volume
and
bath temperature,
then open the
hot water tap"

Advertisement

Table of Contents
loading

Table of Contents