Example: Battery system including second producer in the house (with AC
max. limitation)
Power into the battery
Power consumption AC max. limited to
Power consumption (AC) of the inverter
Second producer in home network
Target value set at feed-in point
Infeed into the public grid
Consumption in home
Allowed battery
A rule always consists of a restriction or parameter and the time control
control rules
and
charging power) must not overlap in time.
Max. charging and discharging limits
The max. charging/max. discharging power can be configured at the same time.
discharge power
114
1000 W
AC MAX: 1000 W
1000 W
-
+
2000 W
"Weekdays"
while the rule is active. Rules with the same restriction (e.g. max.
Limit
1.
Max. charging power
2000 W
2.
Max. discharging power
2000 W
0 W
Max. discharge
power 2000 W
00:00 – 23:59
Mo Tu We Th Fr Sa Su
2000 W
00:00 – 23:59
Mo Tu We Th Fr Sa Su
TARGET: 0W
6
0 0 1
7
Max. charging
power 2000 W
2000 W
1000 W
1000 W
2000 W
0 W
500 W
500 W
500 W
500 W
"Time"
Limit
charging power