Error A071 - Rheem IKONIC RTGH-S11i Manual

Tankless water heaters
Hide thumbs Also See for IKONIC RTGH-S11i:
Table of Contents

Advertisement

ERROR CODE DIAGNOSTICS

ERROR A071

Turn Power OFF
Remove connector "C" and "H" terminal on
flame rod, and reinsert them.
Turn power ON and operate unit.
Did error code
"A071" appear?
Yes
Access maintenance mode to check flame
rod status.
Locate sight glass.
While viewing burner chamber through sight
glass: In 10 seconds intervals, cycle unit 3
times - ON-OFF; ON-OFF; ON-OFF
Is flame visible
when OFF?
Yes
Operate unit.
If the error code "A071" appears and flame is
visible while unit has been OFF longer than 5
seconds:
Replace Gas-Air-ratio valve.
57
Unit had a loose connection or
No
foreign debris that is no longer
present.
Until appears to be operating OK.
In 10 seconds intervals, cycle unit 3
No
times by turning unit:
ON-OFF; ON-OFF; ON-OFF
Does "flame rod status" in
maintenance mode
indicate presence of flame
while unit has been off
>5 seconds?
Yes
Disconnect wires at flame rod(s).
While viewing burner chamber
through sight glass:
In 10 second intervals, cycle unit 3
times by turning unit:
ON-OFF; ON-OFF; ON-OFF
Does "flame rod status" in
maintenance mode
indicate presence of flame
while unit has been off
>5 seconds?
Yes
Replace control board
IKONIC Tankless Water Heater Service Manual
EXPLANATION
Gas Air ratio valve malfunction.
If the flame rod is detecting a flame for 8
seconds when the water heater is turned
off, the water heater displays the "A071"
error code on the User Interface.
Diagnostic check items
Flame rod
Gas-air ratio valve
Flame Rod
Go to STATUS mode and use the [up] or
[down] to TANKLESS STATUS, and press
ENTER.
Use the "▼" or "▲" to FLAME ROD STA-
TUS while the unit is operating.
Operate unit.
No
If error code "A071" appears:
Replace control board.
Clean flame rod.
If the error code "A071" appears
after cleaning flame rod:
Replace flame rod.
No
!
WARNING: When cleaning or replacing the
flame rod/igniter rod, you must replace the
gasket with the Rheem approved gasket (a
spare gasket is provided with the unit). Im-
proper sealing of the flame rod/igniter rod due
to a damaged or missing gasket can cause
unsafe operation or damage the OHL.