Rheem IKONIC RTGH-S11i Manual page 42

Tankless water heaters
Hide thumbs Also See for IKONIC RTGH-S11i:
Table of Contents

Advertisement

IKONIC Tankless Water Heater Service Manual
ERROR CODE DIAGNOSTICS
ERROR A012
Venting
Check the condition of venting (Exp. The connections of
vents, the terminal vent top)
If the connection of venting is removed or the terminal
vent has a blockage, reconnect the vents or clean the
vent (Both inlet side and exhaust side)
Refer to section "Venting for direct vent water heater" in
this manual and refer to U&C manual for installation in-
structions.
Turn Power OFF
Remove connector "H" and terminal on flame
rod, and reinsert them.
Is the flame rod
detecting flame?
No
Remove and clean flame rod.
Reassemble it, and operate unit.
Is error code
"A012" appeared?
Yes
Replace Flame Rod.
Does Error A012 persist?
Replace control board.
Remove & reinsert connector "C".
Operate unit again.
Yes
If A012-Error code appears
Check gas-air ratio valve and
solenoid valve.
No
Flame rod needed to be cleaned
and is OK.
Turn gas ON and check for normal.
Check AC voltage to #2 (black) and #6
(white) while unit is operating.
No
Is the voltage between
108-132 ACV?
Replace gas-air ratio valve
42
Flame rod (Flame is visible)
Go to "STATUS" mode and use the "▼" or "▲" to "Tank-
less Status", and press "ENTER".
Use the "▼" or "▲" to "Flame Rod Status" while the unit
is operating.
!
WARNING: When cleaning or replacing the flame
rod/igniter rod, you must replace the gasket with the
Rheem approved gasket (a spare gasket is provided
with the unit). Improper sealing of the flame rod/igniter
rod due to a damaged or missing gasket can cause
unsafe operation or damage the OHL.
Check resistance to #5 (black) and
#3 (yellow) on connector "C"
Check DC voltage to #5 (black) and #3
(yellow) while unit is operating.
Is the voltage between 90-120 DCV
Yes
Replace Solenoid Valve
Is the resistance between
No
0.8k Ω - 2.4 Ω?
Yes
No
Yes
Yes
Check resistance to the connec-
tor of the white Solenoid Resistor
clipped to the heat exchanger outlet
pipe.
Is the resistance 313 Ω - 347 Ω?
No
Replace the resistor.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents