To Remove The Accessories From The Outdoor Unit; Accessory Pipes: Diameters - Daikin VRV IV+ RYYQ8U7Y1B Series Installer And User Manual

Hide thumbs Also See for VRV IV+ RYYQ8U7Y1B Series:
Table of Contents

Advertisement

14
|
About the box

14.4 To remove the accessories from the outdoor unit

14.5 Accessory pipes: Diameters

Installer and user reference guide
52
8~12 HP
Make sure that all accessories are available in the unit.
a
b
f
a General safety precautions
b Installation manual and operation manual
c Additional refrigerant charge label
d Installation information sticker
e Fluorinated greenhouse gases label
f Multilingual fluorinated greenhouse gases label
g Piping accessory bag
Accessory pipes (mm)
Gas pipe
Front connection
ID Øa
ID Øb
Bottom connection
ID Øa
OD Øb
14~20 HP
c
d
REQUEST FOR THE INDICATION OF INSTALLATION INFORMATION
REQUEST FOR THE INDICATION OF ADDITIONAL REFRIGERANT CHARGING AND LEAK DETECTION OPERATION RESULT
BE SURE TO FILL OUT THE BLANKS, WHICH ARE NEEDED FOR AFTER-SALE SERVICES.
1. RECORD OF INDOOR UNIT MODEL AND INSTALLATION SITE
BE SURE TO FILL OUT THE BLANKS, WHICH ARE NEEDED FOR AFTER-SALE SERVICES.
No.
1
2
3
4
5
6
7
8
9
10
1. CALCULATION OF ADDITIONAL REFRIGERANT CHARGING AMOUNT
CALCULATE THE ADDITIONAL REFRIGERANT CHARGING AMOUNT BASED ON THE FORMULA BELOW BEFORE CHARGING.
MODELNAME
WHEN RE-CHARGING TOTAL AMOUNT OF REFRIGERANT , CHARGE THE TOTAL OF THE AMOUNT CHARGED AT
INSTALLATION
SITE
SHIPMENT (INDICATED ON THE MACHINE NAMEPLATE) AND THE ADDITIONAL AMOUNT SHOWN AS FOLLOWS :
Total indoor unit
No.
11
12
13
14
15
16
17
18
19
20
kg
capacity connection
ratio (CR)
10-12HP 14-16HP 18-20HP
MODELNAME
Total indoor unit capacity
50%< CR < 105%
0
8HP
0
INSTALLATION
SITE
OUTDOOR
AMOUNT
ADDITIONAL CHARGING
TOTAL LENGTH OF LIQUID
PIPE SIZE O22.2 x 0.37
TOTAL LENGTH OF LIQUID
PIPE SIZE O19.1 x 0.26
TOTAL LENGTH OF LIQUID
PIPE SIZE O15.9 x 0.18
when piping length <30m
50%< CR < 70%
105%< CR < 130%
0.5
0
0.5
0
No.
21
22
23
24
25
26
27
28
29
30
UNIT
kg
(m) x 0.37
(m) x 0.26
(m) x 0.18
Total indoor unit capacity
70%< CR < 85%
0.3
0.5
MODELNAME
when piping length >30m
105%< CR < 130%
85%< CR < 105%
1.2
0.7
1
1.5
INSTALLATION
TOTAL LENGTH OF LIQUID
TOTAL LENGTH OF LIQUID
TOTAL LENGTH OF LIQUID
SITE
PIPE SIZE O12.7 x 0.12
PIPE SIZE O9.5 x 0.059
PIPE SIZE O6.4 x 0.022
ONLY FOR RYYQ8~20 MODELS
No.
31
32
33
34
35
36
37
38
39
40
(m) x 0.12
(m) x 0.059
(m) x 0.022
kg
RYYQ8~12
0.9
RYYQ14-16
1.1
RYYQ18-20
1.3
MODELNAME
INSTALLATION
SITE
2. RECORD OF ADDITIONAL REFRIGERANT CHARGE AMOUNT AND RESULT OF LEAK CHECK OPERATION
No.
41
42
43
44
45
46
47
48
49
50
MODELNAME
DATE
INSTALLATION
AMOUNT
No.
SITE
51
52
53
54
55
56
57
58
59
60
RESULT LEAK CHECK
MODELNAME
INSTALLATION
DATE
SITE
AMOUNT
No.
61
62
63
64
RESULT LEAK CHECK
MODELNAME
INSTALLATION
SITE
DATE
2. RECORD FOR SETTINGS (CONTENTS SEE INSTALLATION MANUAL)
AMOUNT
SETTING
VALUE
REMARK
DATE
SETTING
VALUE
REMARK
DATE
RESULT LEAK CHECK
DATE
AMOUNT
RESULT LEAK CHECK
3. FOR DETAILS CONCERNING PIPING SELECTION AND CALCULATION OR HOW TO OPERATE THE LEAK DETECTION FUNCTION, PLEASE REFER TO THE INSTALLATION MANUAL.
3. RECORD OF INSTALLATION DATE
DAY
MONTH
YEAR
4. MODEL NAME
5. MANUFACTURING NUMBER
4. AFTER FILLING IN THIS TABLE, PLEASE PUT IT ON THE SWITCH BOX COVER.
6. AFTER EQUIPPING, PLEASE PUT IT ON THE BACK SIDE OF THE FRONT PLATE.
3P328191-1
g
HP
8
10
12
14
16
18
20
e
0
0.5
0
0.5
1.0
0.5
0.5
1.0
1.5
1
1.5
2.0
3P328192-1
Øa
25.4
4P546228-1C – 2021.11
Øb
19.1
22.2
28.6
RYYQ+RYMQ+RXYQ
VRV IV+ heat pump

Advertisement

Table of Contents
loading

Table of Contents