4.3 Type Tests and Environmental Conditions

Phenomena
Test
ESD
EN 61000-4-2
RF field AM
EN 61000-4-3
modulated
Fast transient
EN 61000-4-4
Surge
EN 61000-4-5
RF conducted
EN 61000-4-6
Radiated emission
EN 55032
Conducted
EN 55032
emission
Dry heat
EN 60068-2-2
Cold
EN 60068-2-1
Damp heat
EN 60068-2-78
Dry heat, cyclic
EN 60068-2-30
Dry heat
EN 60068-2-2
Thermal
shock/
EN 60068-2-14
temp. variation
Degrees of protec-
EN 60529
tion provided by
enclosures
Vibration,
broad-
EN 60068-2-64
band random
Shock
EN 60068-2-27
Table 17: Type Tests and Environmental Conditions
Description
Test levels
Enclosure contact
6 kV (crit. A)
Enclosure
20 V/m (crit. A)
(80 – 1000 MHz)
10 V/m (crit. A)
(1 – 6 GHz)
Signal ports
1 kV (crit. A)
Power ports
2 kV (crit. A)
Ethernet ports
1 kV (crit. A)
Ethernet ports
1 kV (crit. A), shielded cab.
Power ports
1 kV (crit. A)
All ports
10 V/m (crit. A)
(0.15 – 80 MHz)
Enclosure
Class B
Signal ports
Class B
Power ports
Class B
Ethernet ports
Class B
Test Bb, storage +85 C, operation +75 C
Test Ab, storage -40 C, operation -40 C
95 % rel. humidity (+40 C)
+55 C / +25 C, rel. humidity 95 %, 12 h - 12 h
Test Bb, storage +85 C, operation +75 C
Test Nb, -40 C/+75 C, 3h/3h, 2 cycles, 3 K/min
IP30
Spectrum A.3 cat 1, breakpoints A.6 cat 1
2
50 m/s
, 11 ms, half sine, 10 in each dir.
33