7.3 Type tests and environmental conditions

Phenomena
Test
ESD
EN 61000-4-2
RF field AM
EN 61000-4-3
modulated
Fast transient
EN 61000-4-4
Surge
EN 61000-4-5
RF conducted
EN 61000-4-6
Radiated emission
EN 55032
Conducted
EN 55032
emission
Degrees of protec-
EN 60529
tion provided by en-
closures
Dry heat
EN 60068-2-2
Cold
EN 60068-2-1
Damp heat
EN 60068-2-30
Shock
EN 60068-2-14
Table 31: Type tests and environmental conditions
Description
Test levels
Enclosure contact
6 kV
Enclosure air
8 kV
Enclosure
10 V/m (80 – 1000 MHz)
10 V/m (1000 – 6000 MHz)
Signal ports
1 kV
Power ports
1 kV
Ethernet ports
1 kV
Ethernet ports
1 kV
Power ports
1 kV
I/O ports
1 kV
All ports
10 V/m (0,15 – 80 MHz)
Enclosure
Class B
DC power ports
Class B
Ethernet ports
Class B
IP30
storage +85 C,operation +75 C
storage -40 C
+55 C / +25 C, rel. humidity 95%, 6 h - 6 h
-40 C/+75 C, 3h/3h, 2 cycles, 3 K/min