Specifications Of Standard Wiring Components; To Connect The Electrical Wiring To The Outdoor Unit - Daikin RXP25N5V1B Installer's Reference Manual

Hide thumbs Also See for RXP25N5V1B:
Table of Contents

Advertisement

8
|
Electrical installation

8.2.4 Specifications of standard wiring components

8.2.5 To connect the electrical wiring to the outdoor unit

Installer reference guide
48
Wire type
Stranded conductor wire
with round crimp-style
terminal
Tightening torques
Item
M4 (X1M)
M4 (earth)
The earth wire between the wire retainer and the terminal must be longer than
the other wires.
Component
Power supply cable
Interconnection cable (indoor↔outdoor)
Recommended field fuse
Earth leakage circuit breaker
1 Remove the service cover. See
2 Strip insulation (20 mm) from the wires.
a
a Strip wire end to this point
b An excessive strip length may cause electrical shock or leakage
3 Open the wire clamp.
Installation method
c b
B
B
a
a Terminal
b Screw
c Flat washer
Allowed
NOT allowed
1-3
Voltage
Phase
Frequency
Wire sizes
"6.2.2 To open the outdoor
b
a
b
c
Tightening torque (N•m)
1.2~1.5
220~240 V
1~
50 Hz
MUST comply with applicable
legislation
4-core cable ≥1.5 mm² and
applicable for 220~240 V
16 A
MUST comply with applicable
legislation
4
unit" [
 29].
RXP20~35N5V1B+ARXP20~35N5V1B
4P519439-22V – 2022.10
R32 split series