6
|
Unit installation
6.3.2 Precautions when mounting the outdoor unit
6.3.3 To provide the installation structure
6.3.4 To install the outdoor unit
Installer reference guide
30
INFORMATION
Also read the precautions and requirements in the following chapters:
▪
General safety precautions
▪
Preparation
Check the strength and level of the installation ground so that the unit will not
cause any operating vibration or noise.
Fix the unit securely by means of foundation bolts in accordance with the
foundation drawing.
Prepare 4 sets of M8 or M10 anchor bolts, nuts and washers (field supply).
(mm)
a 100 mm above expected level of snow
4× M8/M10
RXP20~35N5V1B+ARXP20~35N5V1B
R32 split series
4P519439-22V – 2022.10