TECHNICAL SPECIFICATIONS
Sensor: 2.5"H x 1"W x .5"D
Code outputs: tamper, tamper restore, alarm, alarm restore, low battery.
Transmitter frequency: 319.5 MHz
Supervisory keep-alive interval: 70 minutes.
RF Peak field strength: typical 36000 uV/m at 3m
UL/ULC listed for residential use only
Operating Temperature: 0C~49C
Relative Humidity: 5-93% Non-Condensing
Storage Temperature: -25-70C
For use indoor, in dry, ordinary locations only.
Door frame height: typical 7ft to 8ft (213 to 244 cm)
Door frame width: typical 1ft to 4ft (30.5 to 122 cm)
Door frame thickness: 1 1/2" to 1 3/4" (3.8 to 4.4 cm)
CHOOSE
STEP
1
INSTALLATION
LOCATION
Sliding
glass
doors
Windows
-
IQ Shock Mini-S can be installed on sliding glass doors,
windows, doors that swing and more.
-
Enclosure base is secured to the installation surface with
double sided tape, manufactured by 3M, part number 4945,
UL recognized under file MH17478 (QOQW2).
-
UL/ULC NOTE:
The IQ Shock Mini - S has been listed by UL/ULC for
residential applications only and in accordance with the
requirements in the Standards UL 634 and UKLC/ORD-
C634 for Door and Window Contact with supplementary
Shock Sensor. The shock sensor is for supplementary
detection only and not for primary protection of the surface
and is not intended for use as a glass break detector.
Exterior Doors
Reproduction without permission is not permitted.
PRODUCT FEATURES
• Reed Switch
• Advanced accelerometer based
shock detection
• 5 distinct sensitivity settings
• LED for easy calibration
Battery Life Expectancy: 5 years (for typical use) with all sensors
enabled. (Not tested by UL/ULC). Replace battery with exact
replacement, 3V Panasonic CR2032 Lithium (x2). Low battery
threshold (2.55v). Note: For UL/ULC certified installations replace
battery yearly.
MAINTENANCE CAUTION!
This product uses Lithium Batteries. Improper handling of lithium
batteries may result in HEAT GENERATION, EXPLOSION or FIRE,
which may lead to personal injuries.
WARNING! DANGER OF EXPLOSION IF BATTERIES ARE INSTALLED
INCORRECTLY. REPLACE ONLY WITH THE SAME OR EQUIVALENT
TYPE RECOMMENDED BY THE MANUFACTURER. KEEP AWAY FROM
SMALL CHILDREN: IF SWALLOWED PROMPTLY SEE A DOCTOR. Do
not try to recharge these batteries.
DIP
STEP
2
SWITCH
CONFIGURATION
Two dip switches allow you to customize the behavior of this device:
DS#1 - Installer Test Mode:
ON:
- Calibrates accelerometer orientation.
- LED is Active for dialing in shock
sensitivity with potentiometer.
- Please note, when test mode is enabled
(ON) the IQ Shock Mini will NOT transmit
signals to the compatible panel.  This
mode is only used for initial installation
and calibration of the shock sensor.
OFF: - Disables installer
test mode.
DS#2 - Reed Switch:
ON:
- Enables reed switch (must be ON for UL
installations).
OFF:
- Disables reed switch.
Sensitivity Level:
CLOCKWISE:
- More Sensitive
COUNTER-
CLOCKWISE:
- Less Sensitive
IMPORTANT NOTE:
The IQ Shock is intended to be installed on doors with or without glass inserts and
on window frames but not on the actual glass surface.
Qolsys Inc. proprietary.
• Ultra small form factor
• Easy to install batteries
• Supervisory health messaging
LED
SENSITIVITY
LEVEL
MAGNET
MAX
MIN
DIP
SWITCHES