IQ GLASS S-LINE QUICK INSTALL GUIDE
CHOOSE
STEP
1
INSTALLATION
LOCATION
Mounting Height:
It is recommended the sensor be mounted at least 6.5ft above
the floor. All protected glass must be within a clear line of sight
of the sensor and within the 20ft max range.

SPECIFICATIONS

Sensor: 2.75"H x 3.88"W x 1.5"D
Frequency: 319.5MHz
Battery: 3V lithium CR123A (x2)
Operating Temperature: 14°F to 122°F
Detection Range: 20ft Max
Compatible with Qolsys control panels
Supervisory signal interval: 70 min (approximately)
This is a quick guide for experienced installers only. Refer to http://dealers.qolsys.com (login required)
STEP
2
Sensitivity:
Ceiling
Two dip switches allow you to customize the sensitivity and detection range of the IQ Glass S. The
factory default is set to MAX. Please refer to the table below to customize the sensitivity.
Walls
Test Mode:
Place the sensor in test mode by removing the battery tabs or disconnecting the batteries
for 30 seconds. Test mode is active for 5 minutes upon the sensor powering on. The LED
blinks every second when the sensor is in test mode. Please refer to the table below for the
LED indicator guide. This sensor will exit test mode after the first 5 minutes of power up.
SWITCH
CONFIGURATION
SENSITIVITY
DETECTION RANGE
MAX
20ft
13ft
MEDIUM
LOW
8ft
LOWEST
5ft
LED Indicator Guide:
CONDITION
Power Up
Test Mode, event detected
Test Mode, alarm
Working, alarm
Low Battery
1
2
OFF
OFF
OFF
ON
ON
OFF
2
ON
ON
RED LED
Flash 3 times, flash once per second
Flash once per second (slow flashing)
Flash 2 second (quick flashing)
ON 5 seconds
Flash once every 30 seconds
ON
1

Advertisement

loading

Summary of Contents for QOLSYS IQ GLASS

  • Page 1: Specifications

    LOCATION Sensitivity: ✓ Ceiling Two dip switches allow you to customize the sensitivity and detection range of the IQ Glass S. The factory default is set to MAX. Please refer to the table below to customize the sensitivity. ✓ Walls...
  • Page 2 FCC ID: 2ABBZ-RF-ARGB TechSupport@Qolsys.com Qolsys Product #: QS1431-840 IC: 11817A-RFARGB This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.