QOLSYS IQ GLASS-S Installation Manual

Iq glass s-line glass break sensor

Advertisement

Quick Links

IQ GLASS S-LINE INSTALLATION MANUAL
IQ GLASS-S
CHOOSE
STEP
1
INSTALLATION
LOCATION
Mounting Height:
The sensor should be mounted between 6.5ft and 8.5ft above the floor.
All protected glass must be within a clear line of sight of the sensor and
within the 20ft max range.
SECURE
STEP
2
TO
SURFACE
Note: for UL/cUL listed the device
shall be secured using the provided
mounting screws.
LEARN
STEP
6
INTO
PANEL
Place your panel in
"autolearn" mode
DETACH
STEP
3
FACE
PLATE
Open and close the case
to "tamper" the device

SPECIFICATIONS

Sensor: 2.75"H x 3.88"W x 1.5"D
Compatible control panels: Qolsys IQ Panel 2
Frequency: 319.5MHz
Battery: 3V GP CR123A (x2)
Operating Temperature: 14°F to 122°F
Detection Range: 20ft Max and 5ft Min
Intended for use with IQ Panel 2
Supervisory signal interval: 70 min (approximately)

Intended for use with 3/16" and 1/4" plate or tempered
glass.
Note: For UL/CUL installations use this device only in conjunction
with compatible Qolsys wireless alarm system IQ Panel 2.
Ceiling
Walls
REMOVE
STEP
4
BATTERY
TAB
Note: Detector LED will flash rapidly for 5
minutes as part of initial power up
sequence.
Customize name and settings as
desired and touch "ADD"
Ceiling mount
Wall mount
REPLACE
STEP
5
FACE
PLATE
ADD

Advertisement

loading

Summary of Contents for QOLSYS IQ GLASS-S

  • Page 1: Specifications

    Supervisory signal interval: 70 min (approximately)
 Intended for use with 3/16” and 1/4” plate or tempered glass. Note: For UL/CUL installations use this device only in conjunction with compatible Qolsys wireless alarm system IQ Panel 2. CHOOSE STEP INSTALLATION LOCATION ✓...
  • Page 2 Test mode is active for 5 minutes upon the sensor powering on. The LED blinks Test Mode Flash once per second every second when the sensor is in test mode. The IQ Glass-S does not transmit an RF Signal Test Mode, alarm event Rapid flash for 2 seconds while it is in Test Mode.