Technical Specifications - Kärcher K 2 Compact Manual

Hide thumbs Also See for K 2 Compact:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10
Appliance is not running
Pull on the lever of the trigger gun; the device
will switch on.
Check whether the voltage indicated on the
type plate corresponds to the voltage of the
mains supply.
Check the mains connection cable for dam-
ages.
Pressure does not build up in the
appliance
Appliance ventilation: Switch the appliance
on with the high-pressure hose detached
and operate (max. 2 minutes) until the water
exits the high-pressure connection without
bubbles. Switch off appliance and reconnect
high-pressure hose.
Check the water supply.
Pull out the sieve in the water connection us-
ing flat-nose pliers and clean under running
water.
Strong pressure fluctuations
Clean high-pressure nozzle: Remove dirt
and debris from the nozzle bore, using a
needle and rinse through with water from the
front.
Check water flow quantity.
Appliance is leaking
Slight leakage from the appliance pump is
normal. If the leakage increases contact the
authorized customer service.
No detergent infeed
Remove the spray lance from the hand spray
gun and work with the hand spray gun only
or use the spray lance with pressure regula-
tion and turn to "Mix".
Clean the detergent suction hose filter.
Check the detergent suction hose for kinks.

Technical specifications

Electrical connection
Voltage
Power consumption
Protection class
Protective class
Mains fuse (slow-blow)
Water connection
Feed pressure
Max. feed temperature
Min. feed volume
Performance data
Working pressure
Max. permissible pressure
Water flow rate
Detergent flow rate
Recoil force of trigger gun
Dimensions and weights
Length
Width
Height
Weight, ready to operate with ac-
cessories
Values determined as per EN 60335-2-79
Hand-arm vibration value
Uncertainty K
Sound pressure level L
Uncertainty K
pA
Sound power level L
tainty K
WA
Subject to technical modifications!
– 8
EN
220-240
V
1~50/60
Hz
6 A
IP X5
II
10 A
0,2-1,2 MPa
40 °C
7 I/min
8 MPa
11 MPa
5,2 I/min
0,3 I/min
10 N
280 mm
176 mm
443 mm
4,7 kg
<2,5
m/s
0,3
m/s
75
dB(A)
pA
3
dB(A)
+ Uncer-
91 dB(A)
WA
2
2
15

Advertisement

Table of Contents
loading

Table of Contents