3. With the 5 holes open, the next step is to insert the back support plate to be fixed from the inside of the wall.
4. On the outside, place the front support plate to match the holes previously opened, insert the screws 4x30mm DIN 7991 until it
is fully threaded, leaving the two pieces together and the wall between them.
5. With all the support fixed to the wall, the display can be placed on the finishing frame, fixing the display from the front and the
box from the rear. We have to connect the two wires of the display and must take into account that the length must be enough to
be able to remove without creating any problem or tension or interference of the cable. Finally, the frame must be fitted with the
display by attaching the bolts to the fixing springs as shown in figure 25.
Temperature probe installation
• The pellet inserts have a probe to measure the ambient temperature. For a correct reading of the ambient temperature, this
probe must be located on the exterior in a place where it does not receive direct radiation or hot air from the equipment. It is
sufficient to drill a hole in the wall and fix the box screwed or glued, leaving the end of the probe inside. Sufficient length of cable
must be left so that the moving part of the equipment can be removed without causing strain on the cable and does not interfere
with the movement of the equipment guides.
Figure 15 – Installing the display outside the device
Figure 16 – Installing the display outside the device
Figure 17 – Installing the display outside the device