SPECIFICATIONS
G½
G½
70
+5
72
146
0
OPERATING CONDITIONS
1.
Water supply pressure : 0.05 ~ 0.75 MPa
2.
Hot water supply temperature shall be higher by 10
than desired temperature of mixed water.
(Recommendation: Hot water supply temperature = 60
3.
Hot water supply pressure shall be the same or lower than cold
water supply .
4.
Ensure that water supply is clean ( No Sand, Dirt, Etc.).
MAINTENANCE
All Finishes : Clean the finish with mild soap and warm water.
Wipe entire surface completely dry with clean soft cloth. Many
cleaners may contain chemicals, such as ammonia, chlorine,
toilet cleaner etc. which could adversely affect the finish and
are not recommended for cleaning
ATTENTION
1. Don t use abrasive cleaners or solvents on faucets and
fittings.
2.
Press safety knob turn left to increase temperature over 40
3.
Please don't open the thermostat cartridge, because it cause
to unstabilize temperature in this product.
As the product model is constantly updated, the actual
4.
product may not look the same as it shown in the diagram, but
the basic installation principles are the same.
S06442R
"EGOII" THERMOSTAT BATH & SHOWER MIXER
INSTALLATION
1
To Fixed
Shower *
*Pipe supplied by owner
3
Handle
G½
0
Bolt
55
25
-5
o
C. at least,
o
C)
Hex. Key
Release The Cap & Bolt
5
Diverter
Base Packing
Handle
Nut
Bolt
o
C.
Cap
Hex. Key
* The Washer fro m Installation step 2
W/ DIVERTER & STOP VALVE
2
Mortar
a
Minimum
Cover *
Mortar Level
To Bat h
Spout *
Washer
Maximum
Remove &
Mortar Level
Keep
Hot Water
Screw
Supply *
* Remove the cover after the mortar has dry
Cold Water
a
The diverter valve is pre-set in factory
Supply *
at center stop position ( Do not turn
the spindle during installation)
4
Open the Valve
OPEN
OPEN
Cap
6
OFF
BATH
SPOUT
Flange
40°C
Packing
Washer*
Handle
Set wat er t emperature until get 40ºC
TX473SESN
7
8
Spindle
40
Handle
Bolt
Handle
If get the water temperature at 40ºC,
Adjust t he safety knob on the handle
release the handle. Make sure the
with number 40º in flange, t hen install
spindle not rotated.
the handle
TROUBLESHOOTING
CHECK
PROBLEM
POINT
Temperature is not consistence
1
Handle is loose
2, 3
2. B OLT
3. B OLT
Safety knob
Cap
Hex. Key
SULUTION
Remove & Clean
Tighten
1. S TRAINER
R9