AMS Neve Libra Live II Series User Manual page 178

Table of Contents

Advertisement

Issue 4
Libra Live Series II User Manual
When locating, the machine may overshoot the specified location. If the overshoot becomes
greater than the value specified in this default the MCS will issue a new locate command rather
than allowing the machine to park at the "overshot" position. This is primarily used to cater for
devices which have a built in "play into park" mode (for example Tascam DA60).
No chase stop (0 disabled, 1 enabled)
1 = Don't issue stop command when parked next to master.
If this option is enabled then this machine will be set to shuttle at zero speed when it is parked
next to the master position.
Stop command (0 or 1)
0 = Shuttle at zero speed and 1 = STOP command.
This option determines how the machine will behave when the STOP key is pressed. If it is set to
0, then the machine will shuttle at zero speed. If it is set to 1, then the machine will be sent a stop
command.
Stop before wind (0 or 1)
1 = issue stop command before going into wind from play.
Setting this option to 1 will cause a stop commend to be sent to this machine between a wind and
a play operation.
Park window (frames)
Allowed error after a locate or chase operation.
This is the maximum allowed difference between the position required by the locate or chase
operation and the actual final machine position. If the difference exceeds this value, than another
locate will be performed.
Edit delay (frames)
Number of frames the machine takes to respond to an EDIT ON command.
This setting should be used to compensate for the time required by the machine to perform an
edit on (i.e. enter record) after receiving the command. The compensation is applied during
programmed external recording.
EE delay (frames)
Number of frames the machine takes to respond to an E to E (input monitor) command.
This parameter is similar to the previous value but applies to the response time to an E to E
command.
Min cue speed
Smallest permitted value of shuttle speed command. Units - 1/64th of play speed, i.e. 4 = 1/16th ,
128 = 2*play speed.
This value should be used to set the minimum shuttle speed for the machine. Higher values will
result in the machine moving in response to shuttle wheel movements below the normal minimum
shuttle speed.
Max cue speed
Largest permitted value of shuttle speed command. Units - multiples of play speed.
This value should be used to set the maximum shuttle speed. Larger values will result in higher
shuttling. This parameter can be used to slow down machine shuttling if desired.
Stop count (frames)
Machine must be motionless for this number of frames before stop is reported.
177
Transport Control

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Libra Live II Series and is the answer not in the manual?

Table of Contents