6. Fundamentals of operation

G Description of the circuit operation
(1) System Configuration
Lossnay operates through the following system.
System
Classification
Details
Basic
1 Lossnay
System
unit
1 Remote
controller
Two
1 Lossnay
remote
unit
con-
2 Remote
trollers
controllers
system
Multiple
Multiple
units
Lossnay
system
units
Systems
Level sig-
interlock
nal output
ed with
device
external
(other
device
manufac-
(air con-
turer's
dition-
PAC, etc.)
ing
or pulse
units)
signal out-
put device
(building
control
system,
etc.)
Mr. Slim
(A-control
or K-con-
trol
remote
con-
troller)
System Diagram
Lossnay
Remote
Transmission cable
M-NET
controller
between the remote
controller and Lossnay
R
Remote controller : PZ-60DR-E or PZ-41SLB-E
Transmission cable terminal
blocks between Lossnay unit
M-NET
: M-NET transmission cable
terminal block
R
: Remote controller
(PZ-60DR-E or PZ-41SLB-E)
Lossnay
Remote
M-NET
controller
R
Lossnay
Lossnay
Remote
Remote
M-NET
M-NET
controller
controller
R
Remote controller (PZ-60DR-E,or PZ-41SLB-E)
External device
(Other manufacturer's
PAC etc.)
Level (pulse) signal
Output device
Remote controller (PZ-60DR-E, or PZ-41SLB-E)
(Operation without a remote controller is also
possible.)
Mr. Slim
indoor unit
Mr. Slim
Lossnay
interlocked
signal
A,K
A-control or K-
control remote
controller
• One remote controller oper-
ates one Lossnay unit.
• Two remote controllers oper-
ate one Lossnay unit. (Last
touch priority operation)
* PZ-60DR-E and PZ-41SLB-E
R
cannot be used together.
• A maximum of 15 Lossnay
Lossnay
units can be operated by a
Remote
M-NET
single remote controller.
controller
(Group operation)
• All units will operate in the
same mode.
• Lossnay is started/stopped
Lossnay
by a signal (*1) from an
external device.
M-NET Remote
controller
• Having a remote control per-
mits last touch priority opera-
tion with the external device
and the remote controller.
• A maximum of 15 Lossnay
R
units can be operated.
*1: An uncharged a-contact,
• Lossnay can be
Lossnay
started/stopped by an A-con-
M-NET Remote
trol remote controller or a K-
controller
control remote controller.
Mr. Slim-Lossnay
• Lossnay High or Low fan
connection cable
speed can be selected from
(Included parts with
the A-control remote controller.
Lossnay)
• Lossnay stand-alone opera-
tion is permitted from the A-
control remote controller.
* Neither PZ-60DR-E nor PZ-
41SLB-E can be used.
— 22 —
Features
12 V DC or 24 V DC level
signal, or an uncharged a-
contact, 12 V DC or 24 V
DC pulse signal.
Prepared
Parts
Lossnay
remote
controller
(PZ-60DR-
E, or PZ-
41SLB-E)
Lossnay
remote
controller
(PZ-60DR-
E or PZ-
41SLB-E)
Lossnay
remote
controller
(PZ-60DR-
E or PZ-
41SLB-E)