Download Print this page
Mitsubishi Electric LGH-15RX5-E Brochure & Specs
Mitsubishi Electric LGH-15RX5-E Brochure & Specs

Mitsubishi Electric LGH-15RX5-E Brochure & Specs

Energy recovery ventilators rx5 series
Hide thumbs Also See for LGH-15RX5-E:

Advertisement

ENERGY RECOVERY VENTILATORS
MODEL
RX
SERIES
5
C o n c e n t r a t i n g w h a t w e c a n d o .
m o r e , e v e r a n d d e f i n i t e l y . . .
HEAD OFFICE : MITSUBISHI DENKI BLDG., 2-2-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
http://Global.MitsubishiElectric.com
Y08-003 Nov.2008(MEE)
Specifications subject to change without notice.

Advertisement

loading

Summary of Contents for Mitsubishi Electric LGH-15RX5-E

  • Page 1 C o n c e n t r a t i n g w h a t w e c a n d o . m o r e , e v e r a n d d e f i n i t e l y . . . HEAD OFFICE : MITSUBISHI DENKI BLDG., 2-2-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN http://Global.MitsubishiElectric.com Y08-003 Nov.2008(MEE)
  • Page 2 LOSSNAY's Energy Recovery Technology and Simple and Effective Simultaneous Ventilations (Supply and Exhaust) Excellent air quality Contribute to Excellent Indoor air Quality and and unbeatable Heat Exchange Efficiency Significantly Reduce the Outdoor air load. Energy-Recovery Concept by Hyper Eco LOSSNAY Core In summer In winter Temperature difference between air supply and room: 1.7 ºC...
  • Page 3 Humidity sensor ventilation system that is suitable to the installed Timers Exhaust air Return air Mitsubishi's newly developed Hyper Eco Element is on environment. board, offering the industry's best total heat exchange Supply air efficiency. Energy conservation performance has been...
  • Page 4 9:00 12:00 13:00 17:00 22:00 The appearance of the remote controller conforms to Mitsubishi air conditioner interface design standards. Friday high high extra low Functions that were set using Dip-Switch on the LOSSNAY main unit can now be configured as needed using the new re- mote controller.
  • Page 5 Control The New Remote Controller PZ-60DR-E enable simple control setting Can Be Used With AG-150A Centralized Controller Controllers are one of the most important and familiar devices in an air conditioning system. Not only does it control to provide Interlocked with Air conditioners optimum air environment but supports operations to minimize running costs and to preserve energy.
  • Page 6 List of Remote Controller Settings and Functions Controllers LOSSNAY remote controller ( PZ-60DR-E ) The remote controller provides a wide range of functions and features other than the main functions described above, such as sophisticated energy conservation control and an easy to see, easy to use interface. New Controller PZ-41SLB-E PZ-52SF-E...
  • Page 7 A Breath of Freshness in Restaurants, Offices, and Schools Restaurants Offices Schools A restaurant can never be too clean and Fresh air–improving the overall quality Creating the best possible environment its air never too fresh of working life for our children to succeed The atmosphere of a restaurant is crucial to securing Many office buildings today are heavily insulated air-tight Children deserve all the help we can give for them to grow...
  • Page 8: Specifications & Dimensions

    Specifications / Dimensions LGH-15 to 100RX LGH-15RX Model LGH-15RX Frequency / Power source 50Hz / Single phase 220-240V Ventilation mode LOSSNAY ventilation By-pass ventilation Fan speed Extra High High Extra Low Extra High High Extra Low Current (A) 0.44-0.46 0.37-0.38 0.25-0.25 0.14-0.15 0.45-0.46...
  • Page 9 LGH-25RX LGH-35RX Model LGH-25RX LGH-35RX Model Frequency / Power source Frequency / Power source 50Hz / Single phase 220-240V 50Hz / Single phase 220-240V Ventilation mode LOSSNAY ventilation By-pass ventilation Ventilation mode LOSSNAY ventilation By-pass ventilation Fan speed Fan speed Extra High High Extra Low...
  • Page 10 LGH-50RX LGH-65RX Model LGH-50RX Model LGH-65RX Frequency / Power source Frequency / Power source 50Hz / Single phase 220-240V 50Hz / Single phase 220-240V Ventilation mode Ventilation mode LOSSNAY ventilation By-pass ventilation LOSSNAY ventilation By-pass ventilation Fan speed Fan speed Extra High High Extra Low...
  • Page 11 LGH-80RX LGH-100RX Model LGH-80RX LGH-100RX Model Frequency / Power source Frequency / Power source 50Hz / Single phase 220-240V 50Hz / Single phase 220-240V Ventilation mode Ventilation mode LOSSNAY ventilation By-pass ventilation LOSSNAY ventilation By-pass ventilation Fan speed Fan speed Extra High High Extra Low...
  • Page 12 LGH-150RX LGH-200RX Model LGH-150RX Model LGH-200RX Frequency / Power source Frequency / Power source 50Hz / Single phase 220-240V 50Hz / Single phase 220-240V Ventilation mode Ventilation mode LOSSNAY ventilation By-pass ventilation LOSSNAY ventilation By-pass ventilation Fan speed Fan speed Extra High High Extra High...
  • Page 13: Wiring Diagrams

    Wiring Diagrams LGH-15RX to 100RX LGH-150RX and 200RX POWER SUPPLY POWER SUPPLY GREEN/YELLOW GREEN/YELLOW 220-240V 50Hz 220-240V 50Hz BROWN Isolator Isolator TAB3 TAB5 BROWN BLACK BLUE TAB1 GREY CN10 BROWN YELLOW TAB2 TAB3 TAB5 BROWN BLACK x103 BLACK BLUE GREY x103 TAB1 SUPPLY...
  • Page 14: Sample Installations

    6.Mitsubishi Electric measures the machine according to the Japan Industrial Standards(JIS B 8628) In winter, it is possible to cool indoor side duct without heat insulation foam on indoor side duct.

This manual is also suitable for: