Technical specifications

Technical specifications of the CP 5623/CP 5624
Connection to PROFIBUS
Connection to PG/PC
Electrical specifications of the PCI plug-in connector
Operating voltage
Current consumption
Effective power loss
Permitted ambient conditions
Operating conditions
Storage and transportation conditions Temperature
CP 5623/CP 5624
Operating Instructions, 12/2022, C79000-G8976-C281-06
Amount
For CP 5623
For CP 5624
Transmission speeds
Design
Properties
Rated voltage
Permitted range
Properties
Typical
CP 5623
CP 5624
Typical
CP 5623
CP 5624
Temperature
(EN 60068-2-1+2)
Maximum temperature change
Relative humidity
(EN 60068-2-78)
Vibration (EN 60068-2-6)
Shock (EN 60068-2-27)
(EN 60068-2-1+2)
Maximum temperature change
1
2
9.6 kbps, 19.2 kbps, 45.45 kbps, 93.75 kbps,
187.5 kbps, 500 kbps, 1.5 Mbps, 3 Mbps,
6 Mbps, 12 Mbps
9-pin D-sub female connector with screw
locking mechanism
RS485 (ungrounded within the SELV limits)
Grounded cable shield
Floating interface signals
PCI Express x1
V 1.0a plug and play
Can also be operated in x4, x8 or x16.
3.3 V DC and 12 V DC
3.0... 3.6 V DC for 3.3 V DC
11.0... 13.0 V DC for 12 V DC
Safety extra low voltage (SELV) to EN 60950
720 mA at 3.3 V and 250 mA at 12 V
750 mA at 3.3 V and 300 mA at 12 V
5.4 W
6.1 W
+5 ... +60 °C
≤ 10 K/h
≤ 85% at 30 °C, no condensation
10 ... 58 Hz
Amplitude 0.075 mm
58 ... 500 Hz,
Acceleration 10 m/s
2
Half-sine: 50 m/s
(5 g), 30 ms
2
-20 ... +60 °C
≤ 20 K/h
5