Page 1
15 Ft. (4.57 m) Diameter Metric Roof Assembly - Explosion Panel Models: 40-SERIES 4.00" CORRUGATION SILO Assembly Manual PNEG-M4015EP Version 1.0 Date: 09-30-20 PNEG-M4015EP...
Page 2
All information, illustrations, photos, and specifications in this manual are based on the latest information available at the time of publication. The right is reserved to make changes at any time without notice. PNEG-M4015EP 15 Ft. (4.57 m) Dia. Explosion Panel Roof...
Safety Precautions Topics Covered in this Chapter ▪ Safety Guidelines ▪ Safety Decals ▪ Safety Sign-off Sheet Safety Guidelines Follow Safety Instructions Use Personal Protective Equipment PNEG-M4015EP 15 Ft. (4.57 m) Dia. Explosion Panel Roof...
Page 6
Chapter 1: Safety Precautions Do Not Enter Bin Prevent Roof Damage due to Vacuum Pressure PNEG-M4015EP 15 Ft. (4.57 m) Dia. Explosion Panel Roof...
Page 7
Chapter 1: Safety Precautions Unload Bin Correctly Do Not Overfill the Bin PNEG-M4015EP 15 Ft. (4.57 m) Dia. Explosion Panel Roof...
Page 8
Chapter 1: Safety Precautions Stay Clear of Hoisted Equipment Sharp Edge Hazard Store Bin Sheets Properly Install and Operate Equipment Properly Rotating Auger Hazard PNEG-M4015EP 15 Ft. (4.57 m) Dia. Explosion Panel Roof...
Chapter 1: Safety Precautions Safety Decals To replace a damaged or missing decal, contact GSI to receive a free replacement. Location Decal No. Decal DC-2306 DC-2161 PNEG-M4015EP 15 Ft. (4.57 m) Dia. Explosion Panel Roof...
Chapter 1: Safety Precautions DC-2210 Safety Sign-off Sheet Date Employee Name Supervisor Name ST-0007 PNEG-M4015EP 15 Ft. (4.57 m) Dia. Explosion Panel Roof...
Roof Assembly for INT180174 Topics Covered in this Chapter ▪ Parts List ▪ Bolt Torque Specifications ▪ Roof Assembly for INT180174 Parts List PNEG-M4015EP 15 Ft. (4.57 m) Dia. Explosion Panel Roof...
Page 12
Chapter 2: Roof Assembly for INT180174 PNEG-M4015EP 15 Ft. (4.57 m) Dia. Explosion Panel Roof...
Page 13
Chapter 2: Roof Assembly for INT180174 PNEG-M4015EP 15 Ft. (4.57 m) Dia. Explosion Panel Roof...
Chapter 2: Roof Assembly for INT180174 Table 2-1 Hardware list Description S.No Part No M08 x 30N flange bolt with LPDE sealing washer S-BFUBM08030BF M10 x 25N flange bolt with LPDE sealing washer S-BFUBM10025BF M10 x 25N flange bolt S-BFSBM10025BN M10 x 35N flange bolt S-BFSBM10035BN M08 flange nut...
Page 15
Chapter 2: Roof Assembly for INT180174 Figure 2-2 Installing the eave angle to the sidewall Figure 2-3 Eave angle tab alignment PNEG-M4015EP 15 Ft. (4.57 m) Dia. Explosion Panel Roof...
Page 16
Chapter 2: Roof Assembly for INT180174 Figure 2-4 Installing the flat top weld to the center collar weldment Figure 2-5 Installing the top bracket and inside top bracket to the rafter PNEG-M4015EP 15 Ft. (4.57 m) Dia. Explosion Panel Roof...
Page 17
Chapter 2: Roof Assembly for INT180174 Figure 2-6 Installing the rafter assembly to the eave bracket Figure 2-7 Placing the center support pole PNEG-M4015EP 15 Ft. (4.57 m) Dia. Explosion Panel Roof...
Page 18
Chapter 2: Roof Assembly for INT180174 Install intermediate panels making sure to lap them in the same way until all panels are in place. NOTE: Do not tighten the bolts until the roof is completely assembled. Make sure to overlap the adjacent panels in counterclockwise direction as shown.
Page 19
Chapter 2: Roof Assembly for INT180174 Figure 2-10 Installing the explosion roof panels into exposed gaps Figure 2-11 Installing the restriction chains to the explosion panels and sidewall PNEG-M4015EP 15 Ft. (4.57 m) Dia. Explosion Panel Roof...
Page 20
Chapter 2: Roof Assembly for INT180174 Figure 2-12 Installing the roof flashing to the center collar and roof panels Figure 2-13 Installing the roof panel seal clips NOTE: Tighten all the bolts now as per the Torque Specifications. See Bolt Torque Specifications, page PNEG-M4015EP 15 Ft.
Chapter 3: Roof Accessories Inspection Port Cover Figure 3-1 Installing the inspection port cover 5/16 x 1 in. hex bolt (S-10260) Handle gasket (CRP-5003) 5/16 in. nut (S-3611) Inspection port cover (ACD-4504) #10-24 x 5/8 in. long bolt (S-2009) Latch (ACD-4514) #10–24 lock nut (S-2010) Inspection port roof panel (ETR-0379-RM) Hinge base (ACD-4506)
12 months from the date of shipment (or, if shipped by vessel, 14 months from the date of arrival at the port of discharge). If, in GSI’s sole judgment, a product is found to have a defect in materials and/or workmanship, GSI will, at its own option and expense, repair or replace the product or refund the purchase price.