15 ft. (4.57 m) diameter metric roof assembly - explosion panel (26 pages)
Summary of Contents for GSi 40 Series
Page 1
75 Ft. (22.86 m) Diameter Metric Roof Assembly - Alpha Models: 40-SERIES 4.00" CORRUGATION SILO Assembly Manual PNEG-M4075A Version 1.0 Date: 06-21-19 PNEG-M4075A...
Page 2
All information, illustrations, photos, and specifications in this manual are based on the latest information available at the time of publication. The right is reserved to make changes at any time without notice. PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Chapter 1: Safety Precautions Safety Decals To replace a damaged or missing decal, contact GSI to receive a free replacement. Location Decal No. Decal DC-2306 DC-2161 PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Chapter 1: Safety Precautions DC-2210 Safety Sign-off Sheet Date Employee Name Supervisor Name ST-0007 PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Roof Assembly Topics Covered in this Chapter ▪ Parts List ▪ Bolt Torque Specifications ▪ Roof Assembly Parts List PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 12
Chapter 2: Roof Assembly PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 13
Chapter 2: Roof Assembly PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 14
Chapter 2: Roof Assembly PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 15
Chapter 2: Roof Assembly PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 16
Chapter 2: Roof Assembly PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 17
Chapter 2: Roof Assembly PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Chapter 2: Roof Assembly Table 2-1 Hardware list Description S.No Part No M08 x 30N flange bolt with LPDE sealing washer S-BFUBM08030BF M10 x 25N flange bolt with LPDE sealing washer S-BFUBM10025BF M10 x 25N flange bolt S-BFSBM10025BN M10 x 35N flange bolt S-BFSBM10035BN M12 x 35N flange bolt with LPDE sealing washer S-BFUBM12035BF...
Chapter 2: Roof Assembly Roof Assembly Figure 2-1 Attaching the inside stiffener to the top outside stiffener Figure 2-2 Attaching the eave bracket to the inside stiffener PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 20
Chapter 2: Roof Assembly Figure 2-3 Eave angle alignment Figure 2-4 Attaching the eave angle to the sidewall sheet PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 21
Chapter 2: Roof Assembly NOTE: Do NOT tighten all the bolts until the roof installation has been completed. Figure 2-5 Connecting the tension member and compression member to the eave bracket Figure 2-6 Attaching the center collar rafter clips to the rafter PNEG-M4075A 75 Ft.
Page 22
Chapter 2: Roof Assembly Figure 2-7 Temperature cable bracket locations Figure 2-8 Installing the temperature cable brackets PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 23
Chapter 2: Roof Assembly Figure 2-9 Installing the supplier link to the temperature cable bracket Figure 2-10 Installing the supplier link to the outer center collar PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 24
Chapter 2: Roof Assembly Figure 2-11 Purlin clips identification and attachment locations of purlins to rafters Figure 2-12 Distance of purlins from rafter end PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 25
Chapter 2: Roof Assembly Figure 2-13 Assembling the purlins with lower purlin clips to the A-frame Figure 2-14 Assembling the purlins with lower and upper purlin clips to the A-frame PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 26
Chapter 2: Roof Assembly Figure 2-15 Assembling the double A-frame Figure 2-16 Diagonal bracing alignment with reference to the center collar PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 27
Chapter 2: Roof Assembly Figure 2-17 Assembling the diagonal bracing to the A-frame Figure 2-18 Assembling the one side of the outer center collar PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 28
Chapter 2: Roof Assembly Figure 2-19 Assembling the another side of the outer center collar Figure 2-20 Assembling the lower stand-off bracket to the outer center collar PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 29
Chapter 2: Roof Assembly Figure 2-21 Center collar placement Figure 2-22 Recommended lifting references for A-frame sections PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 30
Chapter 2: Roof Assembly Figure 2-23 Recommended lifting references for double A-frame sections Figure 2-24 Attaching the A-frames to the center collar PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 31
Chapter 2: Roof Assembly Figure 2-25 Attaching the A-frame to the eave bracket Figure 2-26 Assembling the roof panel clips PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 32
Chapter 2: Roof Assembly Figure 2-27 Installing the intermediate purlins with lower purlin clips Figure 2-28 Installing the intermediate purlins with lower and upper purlin clips PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 33
Chapter 2: Roof Assembly Figure 2-29 Roof panel overview Figure 2-30 Installing the roof panels PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 34
Chapter 2: Roof Assembly Figure 2-31 Installing the roof panels into exposed gaps Figure 2-32 Field drilled holes for roof panels PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 35
Chapter 2: Roof Assembly Figure 2-33 Installing the first roof flashing section Figure 2-34 Installing the remaining roof flashing sections PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 36
Chapter 2: Roof Assembly Figure 2-35 Assembling the center collar brackets to the inner center collar Figure 2-36 Installing the inner center collar to the outer center collar PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 37
Chapter 2: Roof Assembly Figure 2-37 Installing the remaining inner center collar brackets Figure 2-38 Placing the strip of caulk on roof flashing PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 38
Chapter 2: Roof Assembly Figure 2-39 Installing the first top panel Figure 2-40 Placing a strip of caulk on the first top panel PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 39
Chapter 2: Roof Assembly Figure 2-41 Installing the adjacent top panels Figure 2-42 Installing the upper stand-off support brackets PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 40
Chapter 2: Roof Assembly Figure 2-43 Placing a strip of caulk on the top panels Figure 2-44 Lifting and installing the center cap plate PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 41
Chapter 2: Roof Assembly Figure 2-45 Installing the flashing lock NOTE: Tighten all the bolts now as per the Torque Specifications. See Bolt Torque Specifications, page PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Page 42
NOTES PNEG-M4075A 75 Ft. (22.86 m) Diameter Alpha Roof...
Chapter 3: Roof Accessories Inspection Port Cover Figure 3-1 Installing the inspection port cover M08 x 25 flange bolt (S-FBM08025) Latch base bracket (MW-305-M) M08 x 100 HHCS bolt (S-BMPT08100) Inspection port seal strip M08 plastic washer (S-FWPM8) Inspection port sill (MW-OBSILL) M08 nut (S-FNM08) Hinge leaf (MW-273) M08 nylock nut (S-NLNM08)
Page 45
Chapter 3: Roof Accessories Figure 3-2 Installing the inspection port cover (using bin hardware) M08 x 30N flange bolt with sealing washer Latch base bracket (MW-305-M) (S-BFUBM08030BF) M08 x 100 HHCS bolt (S-BMPT08100) Inspection port seal strip M08 flange nut (S-BFSBM08B) Inspection port sill (MW-OBSILL) M08 nylock nut (S-NLNM08) Hinge leaf (MW-273)
12 months from the date of shipment (or, if shipped by vessel, 14 months from the date of arrival at the port of discharge). If, in GSI’s sole judgment, a product is found to have a defect in materials and/or workmanship, GSI will, at its own option and expense, repair or replace the product or refund the purchase price.