7.
User Interface
8.
Critical Settings
The following settings are essential to the successful operation of the system.
Important Note: Set switch setting #3 and tekmarNet
setting once installation has been completed.
Press
• Press and hold down both the
• Release both buttons once the step has been reached.
• Press the
+
• Press and hold down both the
Together
• After 10 seconds of no button activity, the display goes back to normal operation.
Display
ADJUST
ADJUST
SUPPLY
H1 H1
ADJUST
ADJUST
SUPPLY
H1 H1
For a full list of settings and operational details, please refer to the thermostat Installation and Operation Manual
(D528) included with compatible tekmarNet
tekmar Control Systems Ltd., Canada, tekmar Control Systems, Inc., U.S.A. Head Offi ce: 5100 Silver Star Road,
Product design, software and literature are Copyright © 2011 by:
tekmar Control Systems Ltd. and tekmar Control Systems, Inc.
®
system control to Unlock to change Access level to Installer. Return to Lock
or the
button to change the setting, if available.
Range
Access
Installer
°F or °C
Default = °F
User
OFF or On
Installer
Default = On
OFF or On
Installer
Default = OFF
On or Off
Installer
Default = On
Off, Room,
Outdoor,
Installer
Floor, Floor
dSP
®
controls or download the brochure from www.tekmarcontrols.com
Vernon, B.C. Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650 Web Site: www.tekmarcontrols.com
and
buttons for 2 seconds to change from one step to the next.
and
buttons for 2 seconds to go to the next step, OR
Description
TEMPERATURE UNITS
Press the
or the
°C and vice versa.
HEAT SUPPLY PUMP
During heating, select whether or not the system supply
pump should turn on or be off to allow a zone group
pump per manifold.
Available when:
A reset control is present on the tekmarNet
HEAT SUPPLY PUMP DELAY
During heating, select whether or not the system supply
pump should be delayed by 3 minutes before coming
on (for thermal motor or wax actuator).
Available when:
A reset control is present on the tekmarNet
ROOM SENSOR
Select whether the built-in air temperature sensor is
on or off.
Available when:
A floor sensor or room sensor is installed on the
auxiliary sensor input.
AUXILIARY SENSOR
Select the type of auxiliary sensor.
Floor dSP = Show floor sensor reading in upper
number field.
Available when:
Auxiliary sensor automatically detected.
All specifications are subject to change without notice.
2 of 2
button to change from °F to
®
system.
®
system.