Element4 Modore 240 MKII GSB Installation, Operation And Owner's Manual

Element4 Modore 240 MKII GSB Installation, Operation And Owner's Manual

Direct vent gas fireplaces
Hide thumbs Also See for Modore 240 MKII GSB:

Advertisement

Quick Links

Product
Information
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
f i r e - p a r t s . c o m
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed
for the protection of children and other at-risk individuals.
Une barrière conçu pour réduire le risque de brûlure par le verre de visualisation chaude est fournie avec cet appareil et doit
être installé pour la protection des enfants et autres personnes à risque.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Element4 Gas Fireplaces Rev# 06052019
Installation, Operation and Owner's Manual
Modore 240 MKII
Tenore 240 MKII
Direct Vent Gas Fireplaces
INCENDIE OU D'EXPLOSION
Le non-respect des avertissements de sécurité à la
lettre pourrait entraîner de graves blessures , la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ
• Ne pas tenter d'allumer d'appareil.
• Ne touchez á aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bátiment ou vous trouvez.
• Quitter immédiatement le bâtiment.
• Appelez immédiatment votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz
appelez le service des incindies.
- Installation et l'entretien doivent être effectués par un
installateur qualifié, une agence de service ou le fournisseur
de gaz.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour
consultation ultérieure.
1
4006611
GSB
GSB
Une surface vitrée chaude
peut causer des brûlures.
Laisser refroidir la surface
vitrée avant d'y toucher.
Ne permettez jamais á un enfant
de toucher la surface vitrée.
AVERTISSEMENT:
June 2019
EuropeanHome.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Modore 240 MKII GSB and is the answer not in the manual?

Questions and answers

Summary of Contents for Element4 Modore 240 MKII GSB

  • Page 1 INSTALLER: Leave this manual with the appliance. INSTALLATEUR: Laissez cette notice avec l’appareil. CONSUMER: Retain this manual for future reference. CONSOMMATEUR: Conservez cette notice pour consultation ultérieure. June 2019 Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com 4006611...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Important Safety Information ..................... 3 Key Installation Points ......................6 User Information ........................7 Specifications and Dimensions ..................8 Modore 240 MKII GSB Tenore 240 MKII GSB Parts of the Fireplace Clearances ..........................14 Locating the Fireplace Placing the Fireplace...
  • Page 3: Important Safety Information

    Do not place furniture or other objects within 36” of the fireplace glass. SAVE THESE INSTRUCTIONS Make yourself fully aware of all the following instructions and the many features of the Element4 direct vent gas fireplace appliance. INSTALLER: Leave this manual with the appliance.
  • Page 4 Canada, consult with the local authority having The glass must only be removed by a qualified person. jurisdiction for gas product installations to determine their Gloves should be worn when removing the glass. specific requirements for high altitude installations. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 5 DO NOT USE abrasive cleaners on the panels. DO NOT the nearest 1/16” when converted. If greater accuracy is ATTEMPT to clean the glass panels when they are hot. required, use the metric dimensions. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 6: Key Installation Points

    GAS PRESSURES Gas pressures MUST be read with a manometer and confirmed with what is required in the installation manual. FINISHING Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 7: User Information

    WARMTH AND BEAUTY - HOW IT WORKS The Element4 fireplaces are direct vent fireplaces and, as such, the intake and exhaust are both handled through the vent pipe. The fireplace also provides convection air to your room. The illustration shows one of the unique features of the Element4 fireplaces - its use of warm, convection air flow.
  • Page 8: Specifications And Dimensions

    Z21.50a-2008 and CSA2.22a-2008 “Vented Gas Fireplaces” by Intertek Group. A sample listing label image is shown above. A metal listing label is attached to every Element4 fireplace and contains important certification information. The listing label must not be removed from the fireplace.
  • Page 9 10A @ 104°F Cord Length 6 Feet Agency Approvals Fan Set A Fan Set B Snap Switch Speed Control Fan Set C Fan Speed Fan Set D Control Fan Set E Fan Set Electrical Schematic Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 10: Modore 240 Mkii Gsb

    SPECIFICATIONS and DIMENSIONS MODORE 240 MKII GSB Letter Inches Millimeters 77/8 943/4 2406 921/16 2338 1049/16 2656 95/16 453/8 1153 171/2 125/16 177/8 Unit Weight Pounds Kilograms f i r e - p a r t s . c o m 314.1...
  • Page 11: Tenore 240 Mkii Gsb

    2338 1049/16 2656 95/16 453/8 1153 125/16 Unit Weight Pounds Kilograms f i r e - p a r t s . c o m 318.6 Plan View L Elevation Front Elevation R Elevation Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 12: Parts Of The Fireplace

    SPECIFICATIONS and DIMENSIONS PARTS OF THE FIREPLACE The various parts of a Tenore 240 MKII GSB fireplace are shown below. These parts are typical of any Element4 fireplace. f i r e - p a r t s . c o m Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 13 Glass Rope Gasket - holds the Glass Panel in place (4 each - Modore 240, 8 each - Tenore 240) Upright Trim - (2 each - Modore 240, 4 each - Tenore 240) Relief Door - part of the safety system. Do NOT block the operation of the relief doors. Gas Control Assembly Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 14: Clearances

    VALVE, ELECTRICAL WIRING, AND GAS LINES) DOES NOT IMPEDE THE FULL OPERATION OF THE RELIEF DOORS. IT IS YOUR RESPONSIBILITY TO ENSURE THE SAFETY OF THESE CRITICAL COMPONENTS THROUGHOUT THE INSTALLATION PROCESS. REMOVE AND DISPOSE OF ALL WRAPS AND TIES. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 15: Clearances To Combustibles

    We recommend that the fireplace be set into its final location before building the enclosure. Please refer to the “Reduced Clearance to Existing Combustible Wall” section for use of combustibles inside of the above clearances. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 16: Mantel Clearances

    CONSTRUCTION BEAMS COMBUSTIBLE INCHES (TYPICAL) Mantel Depth NON COMBUSTIBLE 12”/300 mm MATERIAL CONSTRUCTION BEAMS NON- COMBUSTIBLE (TYPICAL) DETAIL C ETAIL C 1”/25 mm ALE 1 : 10 TOP OF FIREPLACE OPENING GLASS CONVECTION GAP Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 17: Warm Air Clearances

    Room ceiling to 72” appliance bottom 1830 Square Square Square Square Model Inches Centimeters Inches Centimeters Chase ceiling to top of 1” Modore 240 MKII GSB Warm Air Outlet 1716 1716 Tenore 240 MKII GSB Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 18: Gas And Electric

    Plug the power cord into the dedicated receptacle and ensure that the fans spin freely and operate properly before enclosing the fireplace! Electrical work must be performed by a qualified, licensed electrician. WARNING All wiring shall be in compliance with all local, city, and state codes. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 19: Venting

    EXCELDirect (ICC - Industrial Chimney Company) Pro-Form (BDM - Bernard Dalsin Manufacturing) Direct-Temp (Selkirk Corporation) AmeriVent Direct Vent (Hart & Cooley Inc.) Ventis Direct Vent (Olympia Chimney Supply, Inc.) Please visit www.europeanhome.com/technical-support/ for the power venting installation manuals Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 20: Configuration

    Calculate the Total Vertical Section by adding up all vertically-upward sections in your vent design. CALCULATING THE TOTAL HORIZONTAL SECTION (THS) Calculate the Total Horizontal Section by adding up all horizontal sections in your vent design. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 21 Calculate the Total Vertical Section by adding up all vertical upward sections in your specific vent design. CALCULATING THE TOTAL HORIZONTAL SECTION (THS) Calculate the Total Horizontal Section by adding up all horizontal sections in your specific vent design. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 22: Venting Charts

    6'7" (2 m) 3'4" (1 m) 1'8" (0.5 m) 0 - 1'7" 1'8" (0.5 m) 3'4" (1 m) 5' (1.5 m) 6'7" (2 m) 8'3" (2.5 m) 9'10" (3 m) ft. in. (meters) Total Horizontal Section Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 23: Venting Clearances

    VENTING CLEARANCES HORIZONTAL VENT TERMINATION CLEARANCES AND REQUIREMENTS f i r e - p a r t s . c o m Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 24 National Fuel Gas Code (ANSI Z223.1 in the USA) or the current standard of CAN/CSA-B149.1 in Canada. f i r e - p a r t s . c o m Termination Heights A second termination may be no closer than 12”/305 Multiple Termination Clearance Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 25: Enclosing The Fireplace

    1/4” (6 * The listed brand names are trademarks of their respective companies Skamol Americas, Inc. (844) 475-2665 E-mail: skamotec225@skamol.com www.skamotec225.com Promat Inc. (865) 681-0155 E-mail: sales@promat.us www.promat.us/en James Hardie Building Products (888) 542-7343 www.jameshardie.com Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 26 ENCLOSING the FIREPLACE BUILDING THE ENCLOSURE/FRAMING A safe installation of your Element4 fireplace requires that three things be clearly understood. 1. Most important, these fireplaces are NOT zero-clearance fireplaces. Unlike zero-clearance fireplaces, there is not an outer metal box around the Element4 fireplaces which increases the framing dimensions.
  • Page 27: Rough Opening Dimensions

    2”/50 Minimum Air Gap MUST BE MAINTAINED f i r e - p a r t s . c o m 1”/25 Minimum Air Gap MUST BE MAINTAINED OMbuSTIbLE hIELd INIShEd hIELd INIShEd OMbuSTIbLE Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 28 James Hardie Building Products HardieBacker® 500 1/2” Cement Board 1/2” (12 James Hardie Building Products HardieBacker® 1/4” Cement Board 1/4” (6 f i r e - p a r t s . c o m Fireplace Trim 1/2”/12 Minimum Wall Thickness Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 29 There is a minimum clear area which must be maintained when enclosing the Modore 240 MKII GSB fireplace. Nothing except the Modore 240 MKII GSB cabinet may be within this area. Inside this space, the Modore 240 MKII GSB must be centered, left to right, and the face of the stand-off frame must be at least 191/2”/495...
  • Page 30: Warm Air Opening

    Your installation will use more than this minimum cabinet space in order to accommodate controls, venting, air openings, etc. We recommend that the fireplace be set into its final location before building the enclosure. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 31 - p a r t s . c o m Modore/Tenore 240 with Wall Outlets Modore/Tenore 240 with Outlet in Reveal Warm Air Outlet Area by Model Square Square Model Inches Centimeters Modore 240 MKII Tenore 240 MKII Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 32 - p a r t s . c o m Use the adjustable feet to ensure that the fireplace is level prior to enclosing it. Do NOT lift the fireplace by the face frame but by the bottom of the cabinet. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 33: Cold Climate Installation

    12” 0” Modore 240 shown. The measurements are identical for the Tenore 240. The drawing is not to 36” scale. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 34 Do not kink the lineset and do not bend to a frame and secure it with the four bolts. radius of less than 2”/50 Tighten the bolt through the mounting Fit the gas control tab into the bracket on bosses. the Access Door frame. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 35 45 minutes to ensure the system works properly when heated. DO NOT OPERATE THE BURNERS WITH THE GLASS OFF FOR MORE THAN THREE (3) MINUTES OR DAMAGE WILL OCCUR! Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 36: Installing The Fire Media

    The fireplace has an eight piece hearth panel set which is assembled in the order shown below. Note that panel number 1 is screwed in place, all other panels are packaged separately. Center f i r e - p a r t s . c o m Left Side Right Side Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 37 - bags of black and grey chips With the embers scattered across the burner and hearth panel, lay the logs in the following sequence... f i r e - p a r t s . c o m Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 38: Operating The Fireplace

    ON when the fireplace is turned on. Note! For normal operation the MANUAL knob on the gas valve cannot be in the MAN position; it must be fully in the ON position. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 39 2. The receiver will beep once and the flames will turn off. - If nothing happens or _ll_ appears on the screen, wait until the backlight goes out completely and try again. Power Button Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 40 5. Press buttons simultaneously. Min- When pilot ignition is confirmed, motor turns automatically to maximum utes flash. flame height. 6. To select minutes press button. 7. To confirm press buttons simulta- neously or wait. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 41 NOTE: At end of countdown time period, the fire turns off. The Countdown Timer only works in Manual, Thermostatic, and Eco Modes. Maxi- mum countdown time is 9 hours and 50 minutes. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 42 , , , , , , , . temperature flashes. 6. To confirm press button. 2. To adjust set temperature press but- ton. 3. To confirm press button or wait. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 43 • Daily Timer: Unique on and off times may be set for a single day of the week, for multiple days of the week, or for every day of the week. • Wait to finish setting. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 44 • CHILD PROOF (To activate press buttons simultaneously. displayed and the handset is rendered inoperable (except for off functi- on). • PROGRAM MODE • THERMOSTATIC MODE (also deactivates Program Mode) • ECO MODE • MULTI-BURNER FEATURE • COUNTDOWN TIMER Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 45 The premium materials and build quality of your fireplace will keep these sounds to a minimum. f i r e - p a r t s . c o m To see an Element4 fireplace starting and running normally please visit the link below.
  • Page 46: Maintenance

    Gasketed clamps hold the edges of the Inner Glass Panels in place. Unscrew retaining bolt(s) holding the glass clamp and then remove the clamp. Remove all of the retaining bolts and clamps holding Inner Glass Panels. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 47 Gently push the rope gasket into the outer channel ensuring that the gasket is pushed into the channel until it is flush with the edge of the channel. PROPERLY PLACE, CLAMP AND SEAL THE GLASS PANEL(S) BEFORE LIGHTING THE FIRE! Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 48: Burner

    The pilot has two distinct flames, one engulfing the thermocouple on its left, the other reaching across to the burner. The area around the pilot should be inspected for cleanliness. Lint or foreign material must be removed with a brush or vacuum. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 49: Thermocouple

    MAINTENANCE THERMOCOUPLE MAINTENANCE The Element4 fireplaces have two thermocouples; one next to the pilot and one opposite the pilot side of the burner. The completeness and operation of both must be checked. A qualified installer must confirm that both thermocouples are in place and not damaged.
  • Page 50: Replacement Parts

    MAINTENANCE REPLACEMENT PARTS f i r e - p a r t s . c o m Modore 240 MKII GSB Quantity Part Number Item Description (Required) (Each) Glass E4-GLASS-240 Foot with nut Repl-E4-CP-FT Hearth Panel Repl-E4-CP-HEARTH-240-MKII Hearth Panel Screws...
  • Page 51 Tenore 240 MKII GSB Quantity Part Number Item Description (Required) (Each) Glass E4-GLASS-240 Foot with nut Repl-E4-CP-FT Hearth Panel Repl-E4-CP-HEARTH-240-MKII Hearth Panel Screws Repl-E4-CP-HPS-01 Single Fan E4-ES-1xFAN-CW-01 Double Fan E4-ES-2xFAN-01 Fan Speed Control (Not Shown) E4-ES-FSC-5A-01 Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 52 - p a r t s . c o m Quantity Part Number Item Description (Required) (Each) Pilot Assembly Repl-E4-GS-PABT-01 Ignitor Rod Repl-E4-GS-IGL-01 1st Thermocouple Repl-E4-GS-1T-01 2nd Thermocouple Repl-E4-GS-2TC-mount-01 (w/ mount) Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 53: Warranty

    Customer: Please retain this information. Model MODORE 240 MKII TENORE 240 MKII (check one) Purchased From Date of Purchase Installed By Date of Installation Fireplace Serial Number Fuel Type Total Venting Horizontal Total Venting Vertical Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 54: Massachusetts Certification

    Gas Fitters has issued approval number G1-0515-495 for this appliance. The following must be observed when installing the Element4 fireplaces within the Commonwealth of Massachusetts: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole...
  • Page 55: Troubleshooting Flowchart

    Motor not operating Replace gas valve. properly. Micro switch not Replace gas valve. operating properly. 2nd thermocouple Confirm integrity of 2nd thermocouple and not connected connection. (continued) Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com I:\DEPARTMENTS\Technical Support\Troubleshooting\Guides\20181205_Troubleshooting Flow Chart_E4_8btn Edition.indd...
  • Page 56 Short between interrupter block and TC- Check connection to interrupter block. cable. Sparking stops after pilot is lit. Electronic measuring amplifier defective. Replace the receiver. (continued) Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 57 Turn the control knob to “ON” position, a Manual knob is in the “MAN” position. positive latch is required. Main burner is lit. Confirm correct gas pressure. Increase pilot Pilot flame is too low. flame if necessary. (continued) Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 58 The valve will turn to pilot flame if the set temperature and the ambient temperature remain the same over a 6 hour period. (continued) Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 59 Check venting for complete integrity. Reduce the primary air opening until flames have blue Too much primary air. base and yellow upper two-thirds. Flames are stable but too small and blue. NORMAL OPERATION Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 60 APPENDIX TWO Remote/Receiver Combinations f i r e - p a r t s . c o m Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 61: Installing The Optional Wall Switch

    Increase the flame height: Press and hold the UP button. • Decrease the flame height: Press and hold the DOWN button. • For fine adjustment tap the UP or DOWN button as necessary. • Turn fireplace OFF: Press the ON/OFF button. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 62: Connecting To A Smart Home System

    Frequent ON and OFF cycles will limit life expectancy of the valve and will increase battery consumption. The fireplace should be powered by the AC adapter for improved reliability and customer satisfaction. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 63 No communication between receiver and Wi-Fi Contact service No control possible by the electronics module Contact service No temperature display in the App • No hand transmitter connected “N.a. ” in the App • Batteries hand transmitter empty Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 64 No or bad connection between the receiver and Interrupted responses hand transmitter No electronic control No voltage on the receiver Low communication range, AC adapter f i r e - p a r t s . c o m Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 65 Try to keep jammers as far away as possible devices can not connect via the 5GHz band, the ProControl from the router. Neighboring wireless networks also play a module is not suitable for 5GHz band. role in the Wi-Fi area. Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 66 Learances FIRST FIRE 48 WALL ACCESS DOOR 31 WALL SWITCH Appendix 3 nstaLLing the WARRANTY 54 ressures LISTING LAbEL 8 MAINTENANCE urner iLot herMocoupLes MANTELS 15 NON-COMbuSTIbLE MATERIALS iniMuM Learances Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...
  • Page 67 - p a r t s . c o m EUROPEAN HOME a division of Europa Ja, Inc. 30 Log Bridge Road Building 300 - Suite 303 Middleton, MA 01949 www.europeanhome.com IGE414IIG-180808 Element4 Gas Fireplaces Rev# 06052019 EuropeanHome.com...

This manual is also suitable for:

Tenore 240 mkii gsb

Table of Contents