Deletion Of Date, Time And Disk Setup Data When Turning Off Power; Msr Reading Error - Fujitsu TeamPoS 3000 XT Installation & Maintenance Manual

Table of Contents

Advertisement

TeamPos 3000XT
8.5

Deletion of date, time and disk setup data when turning off power

No
Check item
Is the voltage of the lithium battery on
1
the motherboard normal?
Is the "Clear CMOS" jumper on the
2
motherboard set to "normal" (jumper
between pins 2-3)
Is operation executed normally after
2
replacing the motherboard?
8.6

MSR reading error

Note: the MSR is an optional peripheral.
No
Check item
Is the MSR cable connected
1
correctly?
Does the magnetic card meet ISO
2
standards?
Was the card swiped in the correct
3
direction?
Can it read correctly after cleaning
4
the MSR with a cleaning card?
Does the MSR operate properly
5
using the test program?
Is data read normally after
6
replacing the MSR?
7
Does the MSR work after replacing
the motherboard?
Caution: Before replacing any boards, unplug the power cable and make
D900000172
Judgment Action
Y
N
Y
N
Y
N
Y
N
Y
N
Y
N
Y
N
sure the motherboard standby power LED light is out.
Installation and Maintenance Manual
Judgment Action
Y
Go to No.2.
N
Change the motherboard.
Y
Go to No. 3.
N
Set jumper correctly.
Y
End.
N
Change the whole unit.
Go to No.2.
Connect the cable correctly.
Go to No.3.
Try a known good card and go to
No. 3 if good card still fails.
Go to No.4.
Change the position.
End.
Go to No.5.
Check OPOS/JavaPOS drivers.
Go to No. 6.
End.
Go to No. 7.
End.
Change the whole unit.
8-5