4.1 Piping example

PRV for water
If using the product with AO-2 air out (air separator), higher performance
can be obtained.

4.2 Warning and Caution before use

1. Make sure that end of piping or tube of the product outlet make space of 50mm over from the flood
level rim of the vent.
* Failure to follow this notice may contaminate the surroundings, result in burns for high-temperature
fluid or cause bodily injury or damage to the property when valve leakage happens.
2. Make sure to attach joint and hose to outlet of the product, and lead them to drain ditch.
Do not remove the top of the cap stopper [Pic. 2] when operation.
*Fluid leaks because foreign substance exist on valve disc and seat when elbow cap is loosen,
leakage of liquid to outside from elbow cap may happen. Do not use the product around the place
where leaked liquid can wet another equipment.
*Leakage of liquid result in burns for high-temperature fluid or cause bodily injury or damage to the
property when valve leakage happens.
Stopper

4. Installation

Home boiler
relief valve
Boiler
Elbow cap
Fig. 1
Convector
Float vent
Base board heater
Air out
Circulation pump
Warning
Stopper
4
Elbow cap
Fig. 2