Maintenance
Examine the fan impeller for contamination and clean the fan impeller if neces-
sary with a dull, long object.
To do a check of the air intake
1. Make sure that the air intake is not blocked on the
sides on the product.
2. Stop the product and remove leaves or unwanted
material if it is necessary.
CAUTION:
decreases the blow capacity of the
product and increases the work
temperature of the motor. This can
User interface
User interface
Possible faults
Temperature
deviation.
Tube or fan
cover is re-
Red error LED
moved.
flashes.
Battery error.
Servicing is
necessary.
The product
Dirt in battery
does not start.
connectors.
14
A blocked air intake

Troubleshooting

Possible solution
Let the product become cool.
Assemble the tube or fan cover.
Replace the battery or charge the battery.
Speak to your servicing dealer.
Clean with compressed air or a soft brush.
result in motor failure because the motor
becomes too hot.
To examine the battery and the battery
charger
1. Examine the battery for damages, for example
cracks.
2. Examine the battery charger for damages, for
example cracks.
3. Make sure that the connection cord of the battery
charger is not damaged and that there are no cracks
in it.
To clean the product, the battery and
the battery charger
1. Clean the product with a dry cloth after use.
2. Clean the battery and battery charger with a dry
cloth. Keep the battery guide tracks clean.
3. Make sure that the terminals on the battery and the
battery charger are clean before the battery is put in
the battery charger or the product.
Daily
Weekly
Monthly
X