CAUTION:
decreases the blow capacity of the
product and increases the work
temperature of the motor. This can
result in motor failure because the motor
becomes too hot.
To examine the battery and the battery
charger
1. Examine the battery for damages, for example
cracks.
2. Examine the battery charger for damages, for
example cracks.
User interface
User interface
Green LED Flashes
Red error LED flashes
Green LED and red LED flashes al-
ternatly
Battery charger
LED on the battery
Cause
charger
The green LED is
The battery is not correctly instal-
on and the red LED
led in the battery charger.
flashes.
The battery connectors are dirty.
The ambient temperature is too
high or too low.
The battery is defective.
316
A blocked air intake

Troubleshooting

Possible faults
Low battery voltage.
Temperature deviation.
Dirt in battery connectors or the fan is
blocked.
The battery is empty.
The battery is damaged.
Solution
Remove the battery from the charger and install the bat-
tery in the battery charger again.
Clean the battery connectors.
Use the battery charger in temperatures between 0 °C –
+35 °C.
Replace the battery.
3. Make sure that the connection cord of the battery
charger is not damaged and that there are no cracks
in it.
To clean the product, the battery and
the battery charger
1. Clean the product with a dry cloth after use.
2. Clean the battery and battery charger with a dry
cloth. Keep the battery guide tracks clean.
3. Make sure that the terminals on the battery and the
battery charger are clean before the battery is put in
the battery charger or the product.
Possible solution
Charge the battery.
Let the product become cool.
Clean with compressed air or a soft
brush.
Charge the battery.
Speak to your servicing agent.