Installation
Follow the steps below to strip the wires before assembling the AC plug:
• Strip the outer jacket from the cable for 70mm.
• Strip 22 ± 2mm of insulation from all wires ends.
Conductor cross-section:
Cu: 13.3 mm² ~ 25 mm²
(6 AWG ~ 4 AWG)
Al: 25 mm² (4 AWG)
End sleeve is not able to be installed if 25mm²(4AWG) is applied.
16mm²(6AWG) dimensions of the recommended sleeve are indicated below.
WIRE SIZE
16mm²
6AWG
CAUTION
- Make sure to choose proper size for AC cable.
- Failed to follow these instructions may cause AC plug damage.
- If there is any conflict between installation instruction and electrical code,
please follow the electrical code.
22±2 mm
L1
L2
L3
N
PE
Figure 3-8 : Strip the wires
W
L
F
28
18
Machine and equipment damage may occur.
70 mm (MAX)
D
C
F
L
B
DIMENSIONS(mm)
ΦC
B
10
5.8
24
Outer Jacket
ΦD
ΦW
6.2
8.7