Safety And Guidance Notes - Vent-Axia Lo-Carbon SOLO Plus SELV Installation And Wiring Instructions

Centrifugal bathroom/toilet fan

Advertisement

Installation and Wiring Instructions for the Lo-Carbon SOLO Plus SELV Bathroom Extract
Fan.
IMPORTANT:
READ THESE INSTRUCTIONS BEFORE COMMENCING THE INSTALLATION
DO NOT install this product in areas where the following may be present or occur:
Excessive oil or a grease laden atmosphere.
Corrosive or flammable gases, liquids or vapours.
Ambient temperatures higher than 40°C or less than –5°C.
Possible obstructions which would hinder the access or removal of the Fan.

SAFETY AND GUIDANCE NOTES

A. All wiring to be in accordance with the current I.E.E.
Regulations, or the appropriate standards of your
country and MUST be installed by a suitably qualified
person.
B. The Fan should be provided with a local isolator
switch capable of disconnecting all poles, having a
contact separation of at least 3mm.
C. Ensure that the mains supply (Voltage, Frequency,
and Phase) complies with the rating label.
D. The Fan should only be used in conjunction with the
appropriate Vent-Axia products.
E. It is recommended that the connection to the fan
connector terminals is made with flexible cable.
F. When the Fan is used to remove air from a room
containing a fuel-burning appliance, ensure that the air
replacement is adequate for both the fan and the fuel-
burning appliance.
G. The Fan should not be used where it is liable to be
subject to direct water spray for prolonged periods of
time.
H. Where ducted Fans are used to handle moisture-
laden air, a condensation trap should be fitted.
Horizontal ducts should be arranged to slope slightly
downwards away from the Fan.
I. This appliance is not intended for use by persons
(Including children) with reduced physical, sensory or