Vent-Axia Lo-Carbon Silhouette Series Installation And Wiring Instructions

Vent-Axia Lo-Carbon Silhouette Series Installation And Wiring Instructions

100/150mm axial extract fan

Advertisement

Quick Links

Silhouette
Lo-Carbon RANGE
100/150mm AXIAL EXTRACT FAN
Installation and Wiring Instructions
220-240V~50Hz
PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.
PLEASE SAVE THESE INSTRUCTIONS.
Stock Ref. N°
44 16 24
- 100B
44 16 25
- 100T
44 16 26
- 100HT
44 16 28
- 150B
44 16 29
- 150T
44 16 30
- 150HT
IPX4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lo-Carbon Silhouette Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vent-Axia Lo-Carbon Silhouette Series

  • Page 1 Silhouette Lo-Carbon RANGE 100/150mm AXIAL EXTRACT FAN Installation and Wiring Instructions Stock Ref. N° 44 16 24 - 100B 44 16 25 - 100T 44 16 26 - 100HT 44 16 28 - 150B 44 16 29 - 150T 44 16 30 - 150HT 220-240V~50Hz IPX4...
  • Page 2 L. The exterior grille should be at least 2.3m above the ground to prevent people from being able to access moving parts. If the external grille is positioned between 0-2.3m from the ground, Please use the Vent-Axia wall kit as detailed below to ensure people cannot access the fans impeller from the outside.
  • Page 3 A. INSTALLATION IMPORTANT: The fan should only be used in conjunction with fixed wiring. PANEL/CEILING MOUNTING For panel/ceiling mounting the fan should be installed into a closed duct system of at least 1.2m long (max 3m) or protected by an exterior air grille that must comply with the standard requirements of your country to prevent access to the fans impeller.
  • Page 4 • The fan is a class ll double insulated product and MUST NOT be earthed. Select and follow the appropriate wiring diagram. (Fig. 2 or 3) Check all connections have been made correctly and ensure all terminal connections and cable clamps are securely fastened. Ensure the impeller rotates and is free from obstructions.
  • Page 5 HUMIDITY SET-POINT ADJUSTMENT (HT MODELS ONLY) BEFORE ADJUSTING THE CONTROLLER, SWITCH OFF THE MAINS SUPPLY. HUMIDISTAT SHOULD ONLY BE ADJUSTED BEFORE OR DURING INSTALLATION. Remove the fan grille. The controller is factory set to switch on at about 70% RH. The humidity set point can be adjusted from 65-95%RH by altering the adjuster on the control PCB.
  • Page 6 SALES ENQUIRIES: Tel: 0844 8560590 Fax: 01293 565169 TECHNICAL SUPPORT: Tel: 0844 8560594 Fax: 01293 532814 For details of the warranty and returns procedure please refer to www.vent-axia.com or write to Vent-Axia Ltd, Fleming Way, Crawley, RH10 9YX 442295F 0811...