I N S T A L L A T I O N
The unit should be mounted using a mounting clamp (not provided), and affixing it to the mount-
ing bracket that is provided with the unit. Always ensure that the unit is firmly fixed to avoid vibration
and slipping during operation. Always ensure that the structure to which you are attaching the unit is
secure and is able to support at least 10 times the unit's weight. Also, always use a safety cable that
can hold at least 12 times the weight of the unit when installing the fixture. The equipment must be
installed by a professional, and it must be installed out of reach of the general public.
P O W E R C O R D D A I S Y C H A I N
This feature allows fixtures to be linked to one another using the IEC input and output sockets.
The maximum number of units that can be connected in this manner is as follows:
9 fixtures maximum @ 120V
17 fixtures maximum @ 230V
After this value has been reached, a new power outlet will need to be used to accommodate any
additional fixtures.
All fixtures linked in this manner must be of the same make and model type. DO NOT mix fix-
tures.
T R O U B L E S H O O T I N G
Below is a common problem that users may encounter, with a possible solution.
No light output from the unit:
Check the fuse, which can be found on the rear panel of the unit. If the fuse has been tripped, refer to
the Fuse Replacement section of this manual for detailed instructions on replacing the fuse.