Download Print this page

Specifications - National Instruments NI SCXI 1357 Installation Manual

Controller/adapter kit

Advertisement

You cannot save the chassis configuration until after you enter the switch module
Note
information. A message at the top of the SCXI Chassis Configuration dialog box displays
the configuration status. If a warning appears in the message box, you can save the
configuration. If an error appears in the message box, you cannot save the configuration.

Specifications

Maximum Voltage
Maximum Current
Bus Interface
USB Power Requirements
NI 1357/1358/1359 Kit Installation Guide
c.
Select the Channels tab.
d.
Designate source channels for the topology selected in the
Terminal Block/Topology tab. Notice that you can set different
source channels for each topology.
e.
Designate reserved channels for routing. Notice that you can
reserve different channels for routing in each topology.
f.
Click OK to accept the changes.
8.
To configure additional SCXI switch modules, repeat steps 6 and 7.
9.
If necessary, select the Chassis tab to modify chassis settings.
10. Click OK to accept and save the settings for the chassis.
11. To test the configuration, right-click the chassis name listed under
Devices and Interfaces, and select Test.
After the test, a message indicates successful verification of the
configuration or if an error occurred. If an error occurs, refer to
ni.com/support/install
Terminal to earth ....................................300 V
Terminal to terminal ...............................300 V
Maximum current (per channel) .............2 ADC, 2 AAC
USB specification ...................................USB 2.0 full-speed
USB bus speed........................................12 Mb/s
5 VDC.....................................................25 mA typical, 100 mA max
for troubleshooting information.
10
or VDC
rms
or VDC
rms
ni.com

Advertisement

loading

This manual is also suitable for:

Ni scxi 1358Ni scxi 1359